The DOI matches its Crossref record.
IPM synchronous machine drive response to symmetrical and asymmetrical short circuit faults
Open accessAbstract
A closed-form solution is presented for the steady-state response of interior permanent magnet (IPM) synchronous machines to symmetrical short circuits including the effects of q-axis magnetic saturation. Machine response to single-phase asymmetrical short circuits is also investigated. Experimental data are presented to verify predicted behavior for both types of short circuits. It is shown that single-phase asymmetrical short circuit faults produce more severe fault responses with high pulsating torque and a significant threat of rotor demagnetization. A control strategy that purposely transitions such faults into symmetrical three-phase short circuits can minimize the fault severity and associated demagnetization risks. Implications for the design of IPM machines with improved fault tolerance are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Mitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
Cintron-Rivera, J. G., Foster, S. N., & Strangas, E. G. (2015) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2360813 · Cited by 104
Jiang, Y., Zhang, Z., Jiang, W., Geng, W., & Huang, J. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0754 · Cited by 45
Metadata
- Authors
- Welchko, B. A., Jahns, T. M., Soong, W. L., & Nagashima, J. M.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2003-06
- Volume
- 18
- Issue
- 2
- Pages
- 291-298
- ISSN
- 0885-8969 (ISSN-L)
- OpenAlex
- W2102798192
- Cited by
- 210
- References
- 0
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: IPM synchronous machine drive response to symmetrical and asymmetrical short circuit faults. https://app.cochat.ai/papers/10.1109/tec.2003.811746
- The paper
- Welchko, B. A., Jahns, T. M., Soong, W. L., & Nagashima, J. M. (2003). IPM synchronous machine drive response to symmetrical and asymmetrical short circuit faults. IEEE Transactions on Energy Conversion. https://doi.org/10.1109/tec.2003.811746
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.