A neuro-fuzzy approach to automatic diagnosis and location of stator inter-turn faults in CSI-fed PM brushless DC motors
The DOI matches its Crossref record.
Abstract
The paper presents a neuro-fuzzy-based perspective to the automation of diagnosis and location of stator-winding interturn short circuits in CSI-fed brushless dc motors. Performance of the drive under normal and short-circuit conditions are obtained through classical lumped-parameter network models. Waveforms of the electromagnetic torque and summation of phase voltages are monitored to develop two independent diagnostic algorithms. Diagnostic indices derived from the characteristic waveforms using discrete Fourier transform (DFT) lead to identifying the number of shorted turns. Fault location is achieved through a different set of indices extracted by the short-time Fourier transform (STFT). Adaptive neuro-fuzzy inference systems (ANFIS) are trained based on simulation results to automate the diagnostic process. ANFIS testing along with the good agreement between simulated and measured waveforms show the effectiveness of the proposed techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 13
- 10.1109/60.368345 · DOI · Paper page
- 10.1109/60.911400 · DOI · Paper page
- 10.1109/41.873216 · DOI · Paper page
- 10.1109/IAS.2000.881138 · doi:10.1109/ias.2000.881138
- 10.1109/TIA.2003.811784 · DOI · Paper page
- 10.1109/60.790920 · DOI · Paper page
- 10.1109/TEC.2003.811741 · DOI · Paper page
- 10.1109/TEC.2003.811739 · DOI · Paper page
- 10.1109/41.873207 · DOI · Paper page
- 10.1109/21.256541 · DOI · Paper page
- 10.1109/41.807988 · DOI · Paper page
- 10.1109/TAES.1980.309005 · DOI
- 10.1109/TIA.1982.4504052 · doi:10.1109/tia.1982.4504052
Cited by
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
“[56] Summation of phase voltages DFT fs EV, ON, RL, RS SC, summation of phase voltages has to be calculated”
BackgroundChoi, S., Haque, M. S., Tarek, M. T. B., Mulpuri, V., Duan, Y., Das, S., Garg, V., Ionel, D. M., Masrur, M. A., Mirafzal, B., et al. (2018) · IEEE Transactions on Transportation Electrification · doi:10.1109/tte.2018.2819627 · Cited by 192
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
“However, redundancy in fault detection systems by adding search coil, [21], the need for additional measurement system [22], underestimation of fault and nonsinusoidal armature flux linkage harmonics as well as the adverse effect of unbalance in the supply voltage [23], underestimation of non-stationary behavior of fa…”
BackgroundDa, Y., Shi, X., & Krishnamurthy, M. (2011) · 2011 IEEE Vehicle Power and Propulsion Conference · doi:10.1109/vppc.2011.6043248 · Cited by 96
“To make it more adaptive to achieve more accurate solutions under different operation conditions, hybrid neural/fuzzy machine fault detectors are also under research [45]-[48], which take advantage of the learning capability of ANNs to optimize fuzzy sets.”
MethodComprehensive review on inter‐turn fault indexes in permanent magnet motors
Faiz, J., Nejadi‐Koti, H., & Valipour, Z. (2017) · IET Electric Power Applications · doi:10.1049/iet-epa.2016.0196 · Cited by 86
Jiang, Y., Zhang, Z., Jiang, W., Geng, W., & Huang, J. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0754 · Cited by 45
A Novel Fault Diagnosis Technique for IPMSM Using Voltage Angle
Ullah, Z., Lee, S.-T., & Hur, J. (2018) · 2018 IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2018.8557375 · Cited by 13
“Many techniques have been proposed to diagnose ITSF, which are based on partial discharge [4], voltage signal [5], stator current dq-axis or Park’s vector [6], [7],negative sequence in stator current [8], the components of the sequence impedance matrix [9], searching coil [10], [11], injecting high frequency signal [1…”
Background
Metadata
- Authors
- Awadallah, M. A., Morcos, M. M., Gopalakrishnan, S., & Nehl, T. W.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2005-06
- Volume
- 20
- Issue
- 2
- Pages
- 253-259
- ISSN
- 0885-8969 (ISSN-L)
- 1558-0059
- OpenAlex
- W2171233586
- Cited by
- 105
- References
- 0
- FWCI
- 7.89
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.