The DOI matches its Crossref record.
A Coordinated Control Method for Leveling PV Output Power Fluctuations of PV–Diesel Hybrid Systems Connected to Isolated Power Utility
Abstract
A photovoltaic (PV) system's power output is not constant and fluctuates depending on weather conditions. Fluctuating power causes frequency deviations and reduction in reliability of the isolated power utility or microgrid when large output power from several PV systems is penetrated in the utility. In this paper, to overcome these problems, a simple coordinated control method for leveling the fluctuations of combined power output from multiple PV systems is proposed. The conflicting objective of output power leveling and acquisition power increase is achieved by means of the proposed method. Here, output power command is generated in two steps: central and local. Fuzzy reasoning is used to generate the central leveling output power command considering insolation, variance of insolation, and absolute average of frequency deviation. In local step, a simple coordination is maintained between central power command and local power commands by producing a common tuning factor. Power converters are used to achieve the same output power as local command power employing PI control law for each of the PV generation systems. The proposed method is compared with the method where a modified maximum power point tracking control is used for smoothing the short-term change in each of the PV system's output. Simulation results show that the proposed method is effective for leveling output power fluctuations and feasible to reduce the frequency deviations of the isolated power utility to maintain reliability.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
State of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
Alajmi, B. N., Ahmed, K. H., Finney, S. J., & Williams, B. W. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2090903 · Cited by 635
Intelligent Frequency Control in an AC Microgrid: Online PSO-Based Fuzzy Tuning Approach
Bevrani, H., Habibi, F., Babahajyani, P., Watanabe, M., & Mitani, Y. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2012.2196806 · Cited by 599
Pandey, S. K., Mohanty, S. R., & Kishor, N. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2013.04.029 · Cited by 561
Mitigating methods of power fluctuation of photovoltaic (PV) sources – A review
Shivashankar, S., Mekhilef, S., Mokhlis, H., & Karimi, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.059 · Cited by 422
Metadata
- Authors
- Datta, M., Senjyu, T., Yona, A., Funabashi, T., & Kim, C.-H.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2009-03
- Volume
- 24
- Issue
- 1
- Pages
- 153-162
- ISSN
- 0885-8969 (ISSN-L)
- OpenAlex
- W2124690419
- Cited by
- 168
- References
- 0
- FWCI
- 7.17
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Coordinated Control Method for Leveling PV Output Power Fluctuations of PV–Diesel Hybrid Systems Connected to Isolated Power Utility. https://app.cochat.ai/papers/10.1109/tec.2008.2008870
- The paper
- Datta, M., Senjyu, T., Yona, A., Funabashi, T., & Kim, C.-H. (2009). A Coordinated Control Method for Leveling PV Output Power Fluctuations of PV–Diesel Hybrid Systems Connected to Isolated Power Utility. IEEE Transactions on Energy Conversion. https://doi.org/10.1109/tec.2008.2008870
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.