The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Condition Monitoring of the Power Output of Wind Turbine Generators Using Wavelets
Open accessAbstract
With an increasing number of wind turbines being erected offshore, there is a need for cost-effective, predictive, and proactive maintenance. A large fraction of wind turbine downtime is due to bearing failures, particularly in the generator and gearbox. One way of assessing impending problems is to install vibration sensors in key positions on these subassemblies. Such equipment can be costly and requires sophisticated software for analysis of the data. An alternative approach, which does not require extra sensors, is investigated in this paper. This involves monitoring the power output of a variable-speed wind turbine generator and processing the data using a wavelet in order to extract the strength of particular frequency components, characteristic of faults. This has been done for doubly fed induction generators (DFIGs), commonly used in modern variable-speed wind turbines. The technique is first validated on a test rig under controlled fault conditions and then is applied to two operational wind turbine DFIGs where generator shaft misalignment was detected. For one of these turbines, the technique detected a problem 3 months before a bearing failure was recorded.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Review of condition monitoring of rotating electrical machines
Tavner, P. J. (2008) · IET Electric Power Applications · doi:10.1049/iet-epa:20070280 · Cited by 531
Self-citation
Cited by
Wind Turbine Condition Monitoring: State-of-the-Art Review, New Trends, and Future Challenges
Tchakoua, P., Wamkeue, R., Ouhrouche, M., Slaoui-Hasnaoui, F., Tameghe, T., & Ekemb, G. (2014) · Energies · doi:10.3390/en7042595 · Cited by 604
Wind turbine condition monitoring: technical and commercial challenges
Yang, W., Tavner, P. J., Crabtree, C. J., Feng, Y., & Qiu, Y. (2014) · Wind Energy · doi:10.1002/we.1508 · Cited by 474
Self-citationQiao, W., & Lu, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2422394 · Cited by 407
A review of wind turbine bearing condition monitoring: State of the art and challenges
de Azevedo, H. D. M., Araújo, A. M., & Bouchonneau, N. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.11.032 · Cited by 382
Reliability of Power Electronic Systems: An Industry Perspective
Falck, J., Felgemacher, C., Rojko, A., Liserre, M., & Zacharias, P. (2018) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2018.2825481 · Cited by 336
Metadata
- Authors
- Watson, S. J., Xiang, B. J., Yang, W., Tavner, P. J., & Crabtree, C. J.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2010-09
- Volume
- 25
- Issue
- 3
- Pages
- 715-721
- ISSN
- 0885-8969 (ISSN-L)
- 1558-0059
- OpenAlex
- W2150249602
- Cited by
- 189
- References
- 1
- FWCI
- 25.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Condition Monitoring of the Power Output of Wind Turbine Generators Using Wavelets. https://app.cochat.ai/papers/10.1109/tec.2010.2040083
- The paper
- Watson, S. J., Xiang, B. J., Yang, W., Tavner, P. J., & Crabtree, C. J. (2010). Condition Monitoring of the Power Output of Wind Turbine Generators Using Wavelets. IEEE Transactions on Energy Conversion. https://doi.org/10.1109/tec.2010.2040083
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.