The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network
Abstract
Interaction between doubly fed induction generator (DFIG) Type 3 wind generators and series-compensated networks can lead to subsynchronous resonance (SSR) oscillations-a phenomenon observed in the real world. In this paper, impedance-based Nyquist stability criterion is applied to analyze the SSR phenomena. Impedance models of a DFIG along with its rotor-side converter (RSC) and grid-side converter, and a series-compensated network are derived in terms of space vectors. The DFIG impedance and the network impedance are analyzed to show the impact of wind speed, compensation level, and RSC current controller gain on SSR stability. Nyquist maps are also used to demonstrate the impact on SSR stability. Simulation studies are carried out to show SSR controller interaction. This paper successfully demonstrates that the interaction between the electric network and the converter controller is a leading cause of the SSR phenomena recently observed in wind generation grid integration.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Impedance-Based Stability Criterion for Grid-Connected Inverters
Sun, J. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2136439 · Cited by 2,574
Small-Signal Methods for AC Distributed Power Systems–A Review
Sun, J. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2029859 · Cited by 712
Modeling of DFIG-Based Wind Farms for SSR Analysis
Fan, L., Kavasseri, R., Miao, Z. L., & Zhu, C. (2010) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2050912 · Cited by 472
Self-citationOstadi, A., Yazdani, A., & Varma, R. K. (2009) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2009.2013667 · Cited by 208
Nyquist-Stability-Criterion-Based SSR Explanation for Type-3 Wind Generators
Fan, L., & Miao, Z. (2012) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2012.2193491 · Cited by 136
Self-citation
Cited by
Definition and Classification of Power System Stability – Revisited & Extended
Hatziargyriou, N., Milanovic, J., Rahmann, C., Ajjarapu, V., Canizares, C., Erlich, I., Hill, D., Hiskens, I., Kamwa, I., Pal, B., et al. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3041774 · Cited by 1,244
Sub-Synchronous Interaction Damping Control for DFIG Wind Turbines
Leon, A. E., & Solsona, J. A. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2014.2327197 · Cited by 316
Frequency Domain Stability Analysis of MMC-Based HVdc for Wind Farm Integration
Lyu, J., Cai, X., & Molinas, M. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2498182 · Cited by 267
Metadata
- Authors
- Miao, Z.
- Venue
- IEEE Transactions on Energy Conversion
- Published
- 2012-12
- Volume
- 27
- Issue
- 4
- Pages
- 984-991
- ISSN
- 0885-8969 (ISSN-L)
- 1558-0059
- OpenAlex
- W2035903488
- Cited by
- 329
- References
- 5
- FWCI
- 5.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network. https://app.cochat.ai/papers/10.1109/tec.2012.2211019
- The paper
- Miao, Z. (2012). Impedance-Model-Based SSR Analysis for Type 3 Wind Generator and Series-Compensated Network. IEEE Transactions on Energy Conversion. https://doi.org/10.1109/tec.2012.2211019
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.