CoChat

Evaluation of the Performance of a DC-Link Brake Chopper as a DFIG Low-Voltage Fault-Ride-Through Device

Open access
Pannell, Graham, Zahawi, Bashar, Atkinson, David J., Missailidis, Petros · 2013 · IEEE Transactions on Energy Conversion
Cited by 213

The DOI matches its Crossref record.

Abstract

The performance of the doubly fed induction generator (DFIG) during grid faults is attracting much interest due to the proliferation of wind turbines that employ this technology. International grid codes specify that the generator must exhibit a fault-ride-through (FRT) capability by remaining connected and contributing to network stability during a fault. Many DFIG systems employ a rotor circuit crowbar to protect the rotor converter during a fault. Although this works well to protect the generator, it does not provide favorable grid support behavior. This paper describes an experimental investigation of an alternative FRT approach using a brake chopper circuit across the converter dc link to ensure that the dc-link voltage remains under control during a fault. Two different approaches to chopper control are examined and the resulting FRT performance is compared with that of a conventional crowbar approach. The new chopper-based control methods are experimentally evaluated using a 7.5-kW DFIG test rig facility.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tec.2013.2261301

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Pannell, G., Zahawi, B., Atkinson, D. J., & Missailidis, P.
Venue
IEEE Transactions on Energy Conversion
Published
2013-09
Volume
28
Issue
3
Pages
535-542
ISSN
  • 0885-8969 (ISSN-L)
  • 1558-0059
OpenAlex
W2052584955
Cited by
213
References
0
FWCI
9.59
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.