Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 459

The DOI matches its Crossref record; 42 of the 42 references it cites were found in a registry or an index.

TransAttUnet: Multi-Level Attention-Guided U-Net With Transformer for Medical Image Segmentation

Open access
Chen, Bingzhi, Liu, Yishu, Zhang, Zheng, Lu, Guangming, Kong, Adams Wai Kin·2024·IEEE Transactions on Emerging Topics in Computational Intelligence

Abstract

Accurate segmentation of organs or lesions from medical images is crucial for reliable diagnosis of diseases and organ morphometry. In recent years, convolutional encoder-decoder solutions have achieved substantial progress in the field of automatic medical image segmentation. Due to the inherent bias in the convolution operations, prior models mainly focus on local visual cues formed by the neighboring pixels, but fail to fully model the long-range contextual dependencies. In this article, we propose a novel Transformer-based Attention Guided Network calledTransAttUnet, in which the multi-level guided attention and multi-scale skip connection are designed to jointly enhance the performance of the semantical segmentation architecture. Inspired by Transformer, the self-aware attention (SAA) module with Transformer Self Attention (TSA) and Global Spatial Attention (GSA) is incorporated into TransAttUnet to effectively learn the non-local interactions among encoder features. Moreover, we also use additional multi-scale skip connections between decoder blocks to aggregate the upsampled features with different semantic scales. In this way, the representation ability of multi-scale context information is strengthened to generate discriminative features. Benefitting from these complementary components, the proposed TransAttUnet can effectively alleviate the loss of fine details caused by the stacking of convolution layers and the consecutive sampling operations, finally improving the segmentation quality of medical images. Extensive experiments were conducted on multiple medical image segmentation datasets from various imaging modalities, which demonstrate that the proposed method consistently outperforms the existing state-of-the-art methods.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tetci.2023.3309626

Cites

42 of 42 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 42 references

Metadata

Authors
Chen, B., Liu, Y., Zhang, Z., Lu, G., & Kong, A. W. K.
Venue
IEEE Transactions on Emerging Topics in Computational Intelligence
Published
2024-02
Volume
8
Issue
1
Pages
55-68
ISSN
2471-285X (ISSN-L)
OpenAlex
W4386561400
Cited by
459
References
42
FWCI
40.55
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: TransAttUnet: Multi-Level Attention-Guided U-Net With Transformer for Medical Image Segmentation. https://app.cochat.ai/papers/10.1109/tetci.2023.3309626
The paper
Chen, B., Liu, Y., Zhang, Z., Lu, G., & Kong, A. W. K. (2024). TransAttUnet: Multi-Level Attention-Guided U-Net With Transformer for Medical Image Segmentation. IEEE Transactions on Emerging Topics in Computational Intelligence. https://doi.org/10.1109/tetci.2023.3309626

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.