Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 196

The DOI matches its Crossref record.

On-Orbit Calibration and Performance of Aqua MODIS Reflective Solar Bands

Open access
Xiaoxiong Xiong, Junqiang Sun, Xiaobo Xie, Barnes, W.L., Salomonson, V.V. · 2010 · IEEE Transactions on Geoscience and Remote Sensing

Abstract

Aqua MODIS has successfully operated on-orbit for more than six years since its launch in May 2002, continuously making global observations and improving studies of changes in the Earth's climate and environment. Twenty of the 36 MODIS spectral bands, covering wavelengths from 0.41 to 2.2 ?m, are the reflective solar bands (RSBs). They are calibrated on-orbit using an onboard solar diffuser (SD) and an SD stability monitor. In addition, regularly scheduled lunar observations are made to track the RSB calibration stability. This paper presents Aqua MODIS RSB on-orbit calibration and characterization activities, methodologies, and performance. Included in this paper are characterizations of detector signal-to-noise ratio, short-term stability, and long-term response change. Spectral-wavelength-dependent degradation of the SD bidirectional reflectance factor and scan mirror reflectance, which also varies with the angle of incidence, is examined. On-orbit results show that Aqua MODIS onboard calibrators have performed well, enabling accurate calibration coefficients to be derived and updated for the Level 1B production and assuring high-quality science data products to be continuously generated and distributed. Since launch, the short-term response, on a scan-by-scan basis, has remained extremely stable for most RSB detectors. With the exception of band 6, there have been no new RSB noisy or inoperable detectors. Like its predecessor, i.e., Terra MODIS, launched in December 1999, the Aqua MODIS visible spectral bands have experienced relatively large changes, with an annual response decrease (mirror side 1) of 3.6% for band 8 at 0.412 ?m, 2.3% for band 9 at 0.443 ?m, 1.6% for band 3 at 0.469 ?m, and 1.2% for band 10 at 0.488 ?m. For other RSB bands with wavelengths greater than 0.5 ?m, the annual response changes are typically less than 0.5%. In general, Aqua MODIS optics degradation is smaller than Terra MODIS, and the mirror-side differences are much smaller. Overall, Aqua MODIS RSB on-orbit performance is better than that of Terra MODIS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tgrs.2009.2024307

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 196

Metadata

Authors
Xiong, X., Sun, J., Xie, X., Barnes, W. L., & Salomonson, V. V.
Venue
IEEE Transactions on Geoscience and Remote Sensing
Published
2010-01
Volume
48
Issue
1
Pages
535-546
ISSN
  • 0196-2892 (ISSN-L)
  • 1558-0644
OpenAlex
W2140741445
Cited by
196
References
0
FWCI
15.50
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On-Orbit Calibration and Performance of Aqua MODIS Reflective Solar Bands. https://app.cochat.ai/papers/10.1109/tgrs.2009.2024307
The paper
Xiong, X., Sun, J., Xie, X., Barnes, W. L., & Salomonson, V. V. (2010). On-Orbit Calibration and Performance of Aqua MODIS Reflective Solar Bands. IEEE Transactions on Geoscience and Remote Sensing. https://doi.org/10.1109/tgrs.2009.2024307

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.