Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 226

The DOI matches its Crossref record.

Wireless Medical Sensor Networks in Emergency Response: Implementation and Pilot Results

Gao, Tia, Pesto, Christopher, Selavo, Leo, Chen, Yin, Ko, JeongGil, Lim, JongHyun, Terzis, Andreas, Watt, Andrew, Jeng, James, Chen, Bor-rong, Lorincz, Konrad, Welsh, Matt·2008·2008 IEEE Conference on Technologies for Homeland Security

Abstract

This project demonstrates the feasibility of using cost- effective, flexible, and scalable sensor networks to address critical bottlenecks of the emergency response process. For years, emergency medical service providers conducted patient care by manually measuring vital signs, documenting assessments on paper, and communicating over handheld radios. When disasters occurred, the large numbers of casualties quickly and easily overwhelmed the responders. Collaboration with EMS and hospitals in the Baltimore Washington Metropolitan region prompted us to develop miTag (medical information tag), a cost- effective wireless sensor platform that automatically track patients throughout each step of the disaster response process, from disaster scenes, to ambulances, to hospitals. The miTag is a highly extensible platform that supports a variety of sensor add-ons - GPS, pulse oximetry, blood pressure, temperature, ECG - and relays data over a self-organizing wireless mesh network Scalability is the distinguishing characteristic of miTag: its wireless network scales across a wide range of network densities, from sparse hospital network deployments to very densely populated mass casualty sites. The miTag system is out-of-the-box operational and includes the following key technologies: 1) cost-effective sensor hardware, 2) self-organizing wireless network and 3) scalable server software that analyzes sensor data and delivers real-time updates to handheld devices and web portals. The system has evolved through multiple iterations of development and pilot deployments to become an effective patient monitoring solution. A pilot conducted with the Department of Homeland Security indicates miTags can increase the patient care capacity of responders in the field A pilot at Washington Hospital showed miTags are capable of reliably transmitting data inside radio-interference-rich critical care settings.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/ths.2008.4534447

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 226

Metadata

Authors
Gao, T., Pesto, C., Selavo, L., Chen, Y., Ko, J., Lim, J., Terzis, A., Watt, A., Jeng, J., Chen, B.-R., Lorincz, K., & Welsh, M.
Venue
2008 IEEE Conference on Technologies for Homeland Security
Publisher
IEEE
Published
2008-05
Pages
187-192
OpenAlex
W2165901024
Cited by
226
References
0
FWCI
21.39
Type
conference paper
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Wireless Medical Sensor Networks in Emergency Response: Implementation and Pilot Results. https://app.cochat.ai/papers/10.1109/ths.2008.4534447
The paper
Gao, T., Pesto, C., Selavo, L., Chen, Y., Ko, J., Lim, J., Terzis, A., Watt, A., Jeng, J., Chen, B.-R., Lorincz, K., & Welsh, M. (2008). Wireless Medical Sensor Networks in Emergency Response: Implementation and Pilot Results. 2008 IEEE Conference on Technologies for Homeland Security. https://doi.org/10.1109/ths.2008.4534447

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.