The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Implementation and performance of cooperative control of shunt active filters for harmonic damping throughout a power distribution system
Abstract
This paper proposes cooperative control of multiple active filters based on voltage detection for harmonic damping throughout a power distribution system. The arrangement of a real distribution system would be changed according to system operation, and/or fault conditions. In addition, shunt capacitors and loads are individually connected to, or disconnected from, the distribution system. Independent control might make multiple active filters produce unbalanced compensating currents. This paper presents hardware and software implementations of cooperative control for two active filters. Experiment results verify the effectiveness of the cooperative control with the help of a communication system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Communications technology guidelines for EMS/SCADA systems
Marihart, D. J. (2001) · IEEE Transactions on Power Delivery · doi:10.1109/61.915480 · Cited by 134 · cited 1×
“Although there are many types of communication system such as a radio system, a distribution-line carrier system and so on [13], a serial communication system is used for the following experiments.”
Method
Cited by
Akagi, H. (2005) · Proceedings of the IEEE · doi:10.1109/jproc.2005.859603 · Cited by 1,011
Self-citationAn Islanding Microgrid Power Sharing Approach Using Enhanced Virtual Impedance Control Scheme
He, J., Li, Y. W., Guerrero, J. M., Blaabjerg, F., & Vasquez, J. C. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2243757 · Cited by 482
Tenti, P., Paredes, H. K. M., & Mattavelli, P. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2010.2093153 · Cited by 262
Metadata
- Authors
- Jintakosonwit, P., Fujita, H., Akagi, H., & Ogasawara, S.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2003-03
- Volume
- 39
- Issue
- 2
- Pages
- 556-564
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2179152198
- Cited by
- 197
- References
- 1
- FWCI
- 9.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.