The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Design and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Abstract
This paper proposes a step-by-step procedure for designing the LCL filter of a front-end three-phase active rectifier. The primary goal is to reduce the switching frequency ripple at a reasonable cost, while at the same time achieving a high-performance front-end rectifier (as characterized by a rapid dynamic response and good stability margin). An example LCL filter design is reported and a filter has been built and tested using the values obtained from this design. The experimental results demonstrate the performance of the design procedure both for the LCL filter and for the rectifier controller. The system is stable and the grid current harmonic content is low both in the lowand high-frequency ranges. Moreover, the good agreement that was obtained between simulation and experimental results validates the proposed approach. Hence, the design procedure and the simulation model provide a powerful tool to design an LCL-filter-based active rectifier while avoiding trial-and-error procedures that can result in having to build several filter prototypes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Virtual-flux-based direct power control of three-phase PWM rectifiers
Malinowski, M., Kazmierkowski, M. P., Hansen, S., Blaabjerg, F., & Marques, G. D. (2001) · IEEE Transactions on Industry Applications · doi:10.1109/28.936392 · Cited by 629
Self-citation(2002) · Elsevier eBooks · doi:10.1016/b978-0-12-402772-5.x5000-5 · Cited by 551
Virtual flux based direct power control of three-phase PWM rectifiers
Malinowski, M., Kazmierkowski, M. P., Hansen, S., Blaabjerg, F., & Marques, G. (2002) · Conference Record of the 2000 IEEE Industry Applications Conference. Thirty-Fifth IAS Annual Meeting and World Conference on Industrial Applications of Electrical Energy (Cat. No.00CH37129) · doi:10.1109/ias.2000.883155 · Cited by 535
Self-citationBlasko, V., & Kaura, V. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.568021 · Cited by 508
Genetic Algorithm-Based Design of the Active Damping for an LCL-Filter Three-Phase Active Rectifier
Liserre, M., Dell'Aquila, A., & Blaabjerg, F. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.820540 · Cited by 370
Self-citationMoran, L., Ziogas, P. D., & Joos, G. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.175279 · Cited by 174
Sensorless control strategies for PWM rectifier
Hansen, S., Malinowski, M., Blaabjerg, F., & Kaźmierkowski, M. P. (2002) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.2000.822601 · Cited by 137
Self-citationViability of active EMI filters for utility applications
Farkas, T., & Schlecht, M. F. (1994) · IEEE Transactions on Power Electronics · doi:10.1109/63.311266 · Cited by 97
A new state feedback based transient control of PWM AC to DC voltage type converters
Draou, A., Sato, Y., & Kataoka, T. (1995) · IEEE Transactions on Power Electronics · doi:10.1109/63.471291 · Cited by 73
Advanced Control of Active Filters in a Battery Charger Application
Bojrup, M. (1999) · Cited by 62
Utility interface issues for line connected PWM voltage source converters: a comparative study
Hava, A. M., Lipo, T. A., & Erdman, W. (1995) · Conference proceedings/Conference proceedings - IEEE Applied Power Electronics Conference and Exposition · doi:10.1109/apec.1995.469010 · Cited by 59
Cited by
Definition and Classification of Power System Stability – Revisited & Extended
Hatziargyriou, N., Milanovic, J., Rahmann, C., Ajjarapu, V., Canizares, C., Erlich, I., Hill, D., Hiskens, I., Kamwa, I., Pal, B., et al. (2021) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.3041774 · Cited by 1,244
“The resonance of an inverter filter can also be triggered by the control of the inverter itself or by interactions with nearby controllers [76].”
BackgroundLiserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.861185 · Cited by 1,101
Self-citationPower Electronics Converters for Wind Turbine Systems
Blaabjerg, F., Liserre, M., & Ma, K. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2181290 · Cited by 918
Self-citationGrid current regulation of a three-phase voltage source inverter with an LCL input filter
Twining, E., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810838 · Cited by 901
Future on Power Electronics for Wind Turbine Systems
Blaabjerg, F., & Ma, K. (2013) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2013.2275978 · Cited by 860
Self-citation
Metadata
- Authors
- Liserre, M., Blaabjerg, F., & Hansen, S.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2005-09
- Volume
- 41
- Issue
- 5
- Pages
- 1281-1291
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2117032398
- Cited by
- 2,402
- References
- 11
- FWCI
- 36.55
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.