Microgrid Power Quality Enhancement Using a Three-Phase Four-Wire Grid-Interfacing Compensator
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
This paper presents a three-phase four-wire grid-interfacing power quality compensator for microgrid applications. The compensator is proposed for use with each individual distributed generation (DG) system in the microgrid and consists of two four-phase-leg inverters (a shunt and a series), optimally controlled to achieve an enhancement of both the quality of power within the microgrid and the quality of currents flowing between the microgrid and the utility system. During utility grid voltage unbalance, the four-phase-leg compensator can compensate for all the unwanted positive-, negative-, and zero-sequence voltage-current components found within the unbalanced utility. Specifically, the shunt four-leg inverter is controlled to ensure balanced voltages within the microgrid and to regulate power sharing among the parallel-connected DG systems. The series inverter is controlled complementarily to inject negative- and zero-sequence voltages in series to balance the line currents, while generating zero real and reactive power. During utility voltage sags, the series inverter can also be controlled using a newly proposed flux-charge current-limiting algorithm to limit the flow of large fault currents between the micro- and utility grids. The performance of the proposed compensator has been verified in simulations and experimentally using a laboratory prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Quality Enhancement Using Custom Power Devices
Ghosh, A., & Ledwich, G. (2002) · Springer eBooks · doi:10.1007/978-1-4615-1153-3 · Cited by 1,365
Design, Analysis, and Real-Time Testing of a Controller for Multibus Microgrid System
Li, Y., Vilathgamuwa, D. M., & Loh, P. C. (2004) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.833456 · Cited by 723
Self-citationCurrent control of unbalanced electrical systems
Jacobina, C. B., Correa, M. B. D., Oliveiro, T. M., Lima, A. M. N., & da Silva, E. R. C. (2001) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.925578 · Cited by 198
Cited by
Guerrero, J. M., Chandorkar, M., Lee, T.-L., & Loh, P. C. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2194969 · Cited by 1,976
Self-citationProportional-resonant controllers and filters for grid-connected voltage-source converters
Teodorescu, R., Blaabjerg, F., Liserre, M., & Loh, P. C. (2006) · IEE Proceedings - Electric Power Applications · doi:10.1049/ip-epa:20060008 · Cited by 1,646
Self-citationState of the Art in Research on Microgrids: A Review
Parhizi, S., Lotfi, H., Khodaei, A., & Bahramirad, S. (2015) · IEEE Access · doi:10.1109/access.2015.2443119 · Cited by 1,194
Li, Y. W., & Kao, C.-N. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2022828 · Cited by 1,127
Self-citationGuerrero, J. M., Loh, P. C., Lee, T.-L., & Chandorkar, M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196889 · Cited by 965
Self-citation
Metadata
- Authors
- Li, Y., Vilathgamuwa, D. M., & Loh, P. C.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2005-11
- Volume
- 41
- Issue
- 6
- Pages
- 1707-1719
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2095998107
- Cited by
- 346
- References
- 3
- FWCI
- 7.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.