The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Control and Design of DC Grids for Offshore Wind Farms
Abstract
Recently, the interest in offshore wind farms has been increased significantly. Besides the huge amount of space available, they have the advantage of an increased and more constant wind speed, leading to a higher and more constant production of power. Although, a lot of mechanical problems for constructing these farms have been solved during the past decade, the electrification is still a major issue in research. For large wind farms situated more than 60 km from the shore, an HVdc connection is favorable. Consequently, a pure dc system could be an interesting and cost-effective solution for offshore wind farms. In this paper, a control structure for such a dc grid is presented and analyzed. Furthermore, different configurations are compared and the developed simulation models are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hingorani, N. G., & Gyugyi, L. (1999) · doi:10.1109/9780470546802 · Cited by 4,233
A three-phase soft-switched high-power-density DC/DC converter for high-power applications
De Doncker, R. W. A. A., Divan, D. M., & Kheraluwala, M. H. (1991) · IEEE Transactions on Industry Applications · doi:10.1109/28.67533 · Cited by 2,535
Self-citationOptimal acquisition and aggregation of offshore wind power by multiterminal voltage-source HVDC
Lu, W., & Ooi, B.-T. (2003) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2002.803826 · Cited by 333
Optimal Pulse-Width Modulation for Three-Level Inverters
Bruckner, T., & Holmes, D. G. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2004.839831 · Cited by 257
A three-phase soft-switched high power density DC/DC converter for high power applications
De Doncker, R. W., Divan, D. M., & Kheraluwala, M. H. (2003) · Conference Record of the 1988 IEEE Industry Applications Society Annual Meeting · doi:10.1109/ias.1988.25153 · Cited by 256
Self-citationAnalysis and design of a three-phase offline DC-DC converter with high-frequency isolation
Prasad, A. R., Ziogas, P. D., & Manias, S. N. (1992) · IEEE Transactions on Industry Applications · doi:10.1109/28.148448 · Cited by 137
Analysis and design of a three-phase offline DC-DC converter with high frequency isolation
Prasad, A. R., Ziogas, P. D., & Manias, S. N. (2003) · IEEE Industry Applications Society Annual Meeting (IAS) · doi:10.1109/ias.1988.25155 · Cited by 87
Cited by
DC Microgrids—Part II: A Review of Power Architectures, Applications, and Standardization Issues
Dragicevic, T., Lu, X., Vasquez, J. C., & Guerrero, J. M. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2464277 · Cited by 1,451
High-power wind energy conversion systems: State-of-the-art and emerging technologies
Yaramasu, V., Wu, B., Sen, P. C., Kouro, S., & Narimani, M. (2015) · Proceedings of the IEEE · doi:10.1109/jproc.2014.2378692 · Cited by 991
HVDC Circuit Breakers: A Review Identifying Future Research Needs
Franck, C. M. (2011) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2010.2095889 · Cited by 909
Autonomous Control of Interlinking Converter With Energy Storage in Hybrid AC–DC Microgrid
Loh, P. C., Li, D., Chai, Y. K., & Blaabjerg, F. (2013) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2013.2252319 · Cited by 403
Load-Dependent Active Thermal Control of Grid-Forming Converters
Andresen, M., De Carne, G., & Liserre, M. (2020) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2020.2966573 · Cited by 10
Metadata
- Authors
- Meyer, C., Hoing, M., Peterson, A., & De Doncker, R. W.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2007
- Volume
- 43
- Issue
- 6
- Pages
- 1475-1482
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2118450933
- Cited by
- 351
- References
- 7
- FWCI
- 10.71
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Control and Design of DC Grids for Offshore Wind Farms. https://app.cochat.ai/papers/10.1109/tia.2007.908182
- The paper
- Meyer, C., Hoing, M., Peterson, A., & De Doncker, R. W. (2007). Control and Design of DC Grids for Offshore Wind Farms. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2007.908182
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.