Dynamic Voltage Restorer Utilizing a Matrix Converter and Flywheel Energy Storage
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
A new series power-conditioning system using a matrix converter with flywheel energy storage is proposed to cope with voltage sag problem. Previous studies have highlighted the importance of providing adequate energy storage in order to compensate for deep voltage sags of long duration in weak systems. With the choice of flywheel as a preferred energy storage device, the proposed solution utilizes a single AC/AC power converter for the grid interface as opposed to a more conventional AC/DC/AC converter, leading to higher power density and increased system reliability. This paper develops the dynamic model for the complete system, including the matrix converter in dual synchronous reference frames coupled to the flywheel machine and the grid, respectively. The dynamic model is used to design a vector control system that seamlessly integrates functions of compensating load voltage and managing energy storage during voltage sag and idling modes. The numerical simulation and experimental results from a laboratory-scale hardware prototype are presented to verify system performance.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hoffman, K. A. (1961) · Cited by 2,706
Vector Control and Dynamics of AC Drives
Novotny, D. W., & Lipo, T. A. (1996) · doi:10.1093/oso/9780198564393.001.0001 · Cited by 1,841
Control topology options for single-phase UPS inverters
Ryan, M. J., Brumsickle, W. E., & Lorenz, R. D. (1997) · IEEE Transactions on Industry Applications · doi:10.1109/28.568015 · Cited by 429
Cited by
Energy Storage Systems for Transport and Grid Applications
Vazquez, S., Lukic, S. M., Galvan, E., Franquelo, L. G., & Carrasco, J. M. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2076414 · Cited by 1,347
A Review of Flywheel Energy Storage System Technologies and Their Applications
Amiryar, M., & Pullen, K. (2017) · Applied Sciences · doi:10.3390/app7030286 · Cited by 563
A comprehensive review of Flywheel Energy Storage System technology
Mousavi G, S. M., Faraji, F., Majazi, A., & Al-Haddad, K. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.09.060 · Cited by 449
Haque, M. M., & Wolfs, P. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.04.025 · Cited by 331
A Novel Axial Flux Permanent-Magnet Machine for Flywheel Energy Storage System: Design and Analysis
Nguyen, T. D., Tseng, K.-J., Zhang, S., & Nguyen, H. T. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089939 · Cited by 183
“The use of flywheel energy storage systems (FESSs) is an effective way to deal with the negative impacts of DG, such as in power smoothing, power leveling, and voltage restoring [1]–[4].”
BackgroundXu, L., Guerrero, J., Lashab, A., Wei, B., Bazmohammadi, N., Vasquez, J., & Abusorrah, A. (2022) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2021.3128409 · Cited by 170
“While for flywheel, the energy is adjusted by regulating its speed [17], [54].”
Method
Metadata
- Authors
- Wang, B., & Venkataramanan, G.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2009
- Volume
- 45
- Issue
- 1
- Pages
- 222-231
- ISSN
- 0093-9994 (ISSN-L)
- OpenAlex
- W2138189731
- Cited by
- 170
- References
- 3
- FWCI
- 15.05
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.