CoChat

Active Islanding Detection Using High-Frequency Signal Injection

Open access
Reigosa, David, Briz, Fernando, Charro, Cristian Blanco, Garcia, Pablo, Guerrero, Juan Manuel · 2012 · IEEE Transactions on Industry Applications
Cited by 216

The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.

Abstract

Islanding detection is of great importance for reliable operation of smart grids. Islanding-detection methods can be classified into three different groups, i.e., active, passive, and communication-based methods. Active methods inject a disturbing signal (typically a voltage) and analyze the system response (typically in the current). These techniques have a low nondetection zone (NDZ) but present the inconvenience inherent to injecting a disturbing signal. Passive methods monitor the grid condition from the grid variables. These techniques are easy to implement but present a large NDZ. Communication methods have the inconvenience of relying on communications, currently being of limited use. This paper proposes a new active islanding-detection method, based on the measurement of the grid high-frequency impedance by means of the injection of a high-frequency voltage. The advantages of the method are almost negligible adverse effects due to the injected high-frequency voltage and accurate and fast islanding detection, i.e., in the range of a few milliseconds. Furthermore, the estimated high-frequency impedance can be used for the adaptive control of the power converter.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tia.2012.2209190

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 216

Metadata

Authors
Reigosa, D., Briz, F., Charro, C. B., Garcia, P., & Guerrero, J. M.
Venue
IEEE Transactions on Industry Applications
Published
2012-09
Volume
48
Issue
5
Pages
1588-1597
ISSN
  • 0093-9994 (ISSN-L)
  • 1939-9367
OpenAlex
W2024701319
Cited by
216
References
11
FWCI
8.75
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.