Grid Voltage Synchronization for Distributed Generation Systems Under Grid Fault Conditions
Open accessThe DOI matches its Crossref record.
Abstract
The actual grid code requirements for the grid connection of distributed generation systems, mainly wind and photovoltaic (PV) systems, are becoming very demanding. The transmission system operators (TSOs) are especially concerned about the low-voltage-ride-through requirements. Solutions based on the installation of STATCOMs and dynamic voltage regulators (DVRs), as well as on advanced control functionalities for the existing power converters of distributed generation plants, have contributed to enhance their response under faulty and distorted scenarios and, hence, to fulfill these requirements. In order to achieve satisfactory results with such systems, it is necessary to count on accurate and fast grid voltage synchronization algorithms, which are able to work under unbalanced and distorted conditions. This paper analyzes the synchronization capability of three advanced synchronization systems: the decoupled double synchronous reference frame phase-locked loop (PLL), the dual second order generalized integrator PLL, and the three-phase enhanced PLL, designed to work under such conditions. Although other systems based on frequency-locked loops have also been developed, PLLs have been chosen due to their link with dq0 controllers. In the following, the different algorithms will be presented and discretized, and their performance will be tested in an experimental setup controlled in order to evaluate their accuracy and implementation features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Grid-Synchronization Stability of Converter-Based Resources—An Overview
Wang, X., Taul, M. G., Wu, H., Liao, Y., Blaabjerg, F., & Harnefors, L. (2020) · IEEE Open Journal of Industry Applications · doi:10.1109/ojia.2020.3020392 · Cited by 862
Self-citationTaul, M. G., Wang, X., Davari, P., & Blaabjerg, F. (2019) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2892142 · Cited by 415
Self-citationFast and Robust Phase Estimation Algorithm for Heavily Distorted Grid Conditions
Zheng, L., Geng, H., & Yang, G. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2585078 · Cited by 83
Metadata
- Authors
- Luna, A., Rocabert, J., Candela, J. I., Hermoso, J. R., Teodorescu, R., Blaabjerg, F., & Rodriguez, P.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2015-07
- Volume
- 51
- Issue
- 4
- Pages
- 3414-3425
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2049042130
- Cited by
- 201
- References
- 0
- FWCI
- 20.72
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Grid Voltage Synchronization for Distributed Generation Systems Under Grid Fault Conditions. https://app.cochat.ai/papers/10.1109/tia.2015.2391436
- The paper
- Luna, A., Rocabert, J., Candela, J. I., Hermoso, J. R., Teodorescu, R., Blaabjerg, F., & Rodriguez, P. (2015). Grid Voltage Synchronization for Distributed Generation Systems Under Grid Fault Conditions. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2015.2391436
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.