Delta Power Control Strategy for Multistring Grid-Connected PV Inverters
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
With a still increasing penetration level of grid-connected photovoltaic (PV) systems, more advanced active power control functionalities have been introduced in certain grid regulations. A delta power constraint, where a portion of the active power from the PV panels is reserved during operation, is required for grid support (e.g., during frequency deviation). In this paper, a cost-effective solution to realize delta power control (DPC) for grid-connected PV systems is presented, where the multistring PV inverter configuration is adopted. This control strategy is a combination of maximum power point tracking (MPPT) and constant power generation (CPG) modes. In this control scheme, one PV string operating in the MPPT mode estimates the available power, whereas the other PV strings regulate the total PV power by the CPG control strategy in such a way that the delta power constraint for the entire PV system is achieved. Simulations and experiments have been performed on a 3-kW single-phase grid-connected PV system. The results have confirmed the effectiveness of the proposed DPC strategy, where the power reserve according to the delta power constraint is achieved under several operating conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2001) · Springer eBooks · doi:10.1007/b100747 · Cited by 6,112
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220 · cited 1×
“Then, one dc-ac inverter injects the extracted PV power to the ac grid by regulating the dc-link voltage to be constant through the control of the grid current ig [29].”
Self-citationA Review of Single-Phase Grid-Connected Inverters for Photovoltaic Modules
Kjaer, S. B., Pedersen, J. K., & Blaabjerg, F. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853371 · Cited by 3,621 · cited 3×
“with the rated power of 1 - 30 kW) consist of multiple PV strings [25], [26], which can be controlled independently with Fig.”
BackgroundMethodSelf-citationKouro, S., Leon, J. I., Vinnikov, D., & Franquelo, L. G. (2015) · IEEE Industrial Electronics Magazine · doi:10.1109/mie.2014.2376976 · Cited by 1,197 · cited 1×
“rations can be adopted depending on the power rating of the PV power plant [29]–[31].”
BackgroundRenewables 2015 Global Status Report
Raturi, A. (2015) · Cited by 1,098
High-Performance Adaptive Perturb and Observe MPPT Technique for Photovoltaic-Based Microgrids
Abdelsalam, A. K., Massoud, A. M., Ahmed, S., & Enjeti, P. N. (2011) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2011.2106221 · Cited by 879
Optimized Maximum Power Point Tracker for Fast-Changing Environmental Conditions
Séra, D., Teodorescu, R., Hantschel, J., & Knoll, M. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924036 · Cited by 477 · cited 1×
“strategy, more advanced MPPT and CPG control strategies with fast dynamics are required, which is a subject for the future work [41]–[43].”
BackgroundMitigating methods of power fluctuation of photovoltaic (PV) sources – A review
Shivashankar, S., Mekhilef, S., Mokhlis, H., & Karimi, M. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.01.059 · Cited by 422 · cited 1×
“controller to control the power flow), increasing the complexity of the overall system [10], [11].”
BackgroundOmran, W. A., Kazerani, M., & Salama, M. M. A. (2011) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2010.2062515 · Cited by 395 · cited 1×
“controller to control the power flow), increasing the complexity of the overall system [10], [11].”
BackgroundHigh-Performance Constant Power Generation in Grid-Connected PV Systems
Sangwongwanich, A., Yang, Y., & Blaabjerg, F. (2016) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2465151 · Cited by 285 · cited 1×
“In contrast to the CPG algorithm in [12]–[14], where a”
ResultSelf-citation
Cited by
Haghighat, M., Niroomand, M., Dehghani Tafti, H., D. Townsend, C., & Fernando, T. (2024) · Journal of Modern Power Systems and Clean Energy · doi:10.35833/mpce.2022.000845 · Cited by 30
Metadata
- Authors
- Sangwongwanich, A., Yang, Y., Blaabjerg, F., & Sera, D.
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2017-07
- Volume
- 53
- Issue
- 4
- Pages
- 3862-3870
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2592753411
- Cited by
- 175
- References
- 29
- FWCI
- 3.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Delta Power Control Strategy for Multistring Grid-Connected PV Inverters. https://app.cochat.ai/papers/10.1109/tia.2017.2681044
- The paper
- Sangwongwanich, A., Yang, Y., Blaabjerg, F., & Sera, D. (2017). Delta Power Control Strategy for Multistring Grid-Connected PV Inverters. IEEE Transactions on Industry Applications. https://doi.org/10.1109/tia.2017.2681044
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.