Online Detection of Rotor Eccentricity and Demagnetization Faults in PMSMs Based on Hall-Effect Field Sensor Measurements
Open accessAbstract
Rotor eccentricity and local demagnetization in permanent magnet synchronous motors (PMSMs) increase unbalanced magnetic pull and motor vibration resulting in accelerated aging of motor components. If the asymmetry in the rotor remains undetected, it can increase in severity, and increase the risk of stator-rotor contact, which causes forced outage of the motor and driven process. Detection of PMSM rotor asymmetry currently relies on offline testing and online vibration/current spectrum analysis. However, they are inconvenient or cannot provide reliable detection of rotor faults for all PMSM designs. In this paper, the feasibility of using the signals from analog Hall-effect field sensors for detecting eccentricity and local demagnetization is investigated. It is shown that Hall sensors present in machines for motion control can be used for directly measuring the variation in the flux inside the motor due to rotor magnetic asymmetry with minimal hardware modifications. Three-dimensional finite-element analysis and experimental results performed on an interior PMSM show that the proposed method can provide sensitive and reliable detection of dynamic/mixed eccentricity and local PM demagnetization.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The cited source says what the claim attributes to it.
In the citing paper
“In [142], a Hall sensor was proposed to detect magnetic asymmetry caused by dynamic or mixed eccentricity and local demagnetization.”
From Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges (2022) · cites this paper as [142]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vibration and current monitoring for detecting airgap eccentricity in large induction motors
Cameron, J. R., Thomson, W. T., & Dow, A. B. (1986) · IEE Proceedings B Electric Power Applications · doi:10.1049/ip-b.1986.0022 · Cited by 515
Detecting Rotor Faults in Low Power Permanent Magnet Synchronous Machines
le Roux, W., Harley, R. G., & Habetler, T. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2006.886620 · Cited by 274
Hong, J., Park, S., Hyun, D., Kang, T.-J., Lee, S. B., Kral, C., & Haumer, A. (2012) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2012.2191253 · Cited by 219
Self-citationRajagopalan, S., Roux, W. L., Habetler, T. G., & Harley, R. G. (2007) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.904183 · Cited by 164
Nonstationary Motor Fault Detection Using Recent Quadratic Time–Frequency Representations
Rajagopalan, S., Restrepo, J. A., Aller, J. M., Habetler, T. G., & Harley, R. G. (2008) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2008.921431 · Cited by 161
Discernment of Broken Magnet and Static Eccentricity Faults in Permanent Magnet Synchronous Motors
Goktas, T., Zafarani, M., & Akin, B. (2016) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2015.2512602 · Cited by 140
Comprehensive Analysis of Magnet Defect Fault Monitoring Through Leakage Flux
Göktaş, T., Zafarani, M., Lee, K. W., Akin, B., & Sculley, T. L. (2016) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2016.2617318 · Cited by 119
Song, X., Fang, J., & Bangcheng, H. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2479642 · Cited by 110
Ebrahimi, B. M., & Faiz, J. (2012) · IET Electric Power Applications · doi:10.1049/iet-epa.2010.0159 · Cited by 100
Delgado-Prieto, M., Espinosa, A. G., Ruiz, J.-R. R., Urresty, J.-C., & Ortega, J. A. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2066538 · Cited by 96
Research works printed but not linked: 1
- shi, 0, EKF-based hybrid controller for PM brushless motors combining Hall sensors and a flux-observer-based sensorless technique, Proc IEEE Int Conf Elect Mach Drives, 1466
Cited by
Sorted by citations
Fault Diagnosis and Fault-Tolerant Control of PMSM Drives–State of the Art and Future Challenges
Orlowska-Kowalska, T., Wolkiewicz, M., Pietrzak, P., Skowron, M., Ewert, P., Tarchala, G., Krzysztofiak, M., & Kowalski, C. T. (2022) · IEEE Access · doi:10.1109/access.2022.3180153 · Cited by 328
Rafaq, M. S., & Jung, J. (2019) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2019.2944413 · Cited by 269
Online Parameter Estimation for Permanent Magnet Synchronous Machines: An Overview
Zhu, Z. Q., Liang, D., & Liu, K. (2021) · IEEE Access · doi:10.1109/access.2021.3072959 · Cited by 195
Fault Detection and Diagnosis of the Electric Motor Drive and Battery System of Electric Vehicles
Khaneghah, M. Z., Alzayed, M., & Chaoui, H. (2023) · Machines · doi:10.3390/machines11070713 · Cited by 102
Online Rotor Fault Diagnosis of Permanent Magnet Synchronous Motors Based on Stator Tooth Flux
Zeng, C., Huang, S., Lei, J., Wan, Z., & Yang, Y. (2021) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2021.3058541 · Cited by 84
Metadata
- Authors
- Park, Y., Fernandez, D., Lee, S. B., Hyun, D., Jeong, M., Kommuri, S. K., Cho, C., Diaz Reigosa, D., & Briz, F.
- Affiliations
- Korea University (KR)
- Universidad de Oviedo (ES)
- ORCID
- Venue
- IEEE Transactions on Industry Applications
- Published
- 2019-05
- Volume
- 55
- Issue
- 3
- Pages
- 2499-2509
- ISSN
- 0093-9994 (ISSN-L)
- 1939-9367
- OpenAlex
- W2905272634
- Cited by
- 116
- References
- 19
- Citations by year
- 2026: 5 · 2025: 14 · 2024: 19 · 2023: 19 · 2022: 15 · 2021: 20 · 2020: 15 · 2019: 9
- FWCI
- 4.21
- Type
- journal article
- Language
- en
- Open access
- green
- hdl.handle.net
- Licence
- Locations
- IEEE Transactions on Industry Applications (publishedVersion)
- Consultation of the Doctoral Thesis Database (TESEO) (Ministerio de Educación, Cultura y Deporte) (submittedVersion, cc-by-nc-nd)
- Funders
- Ministry of Trade, Industry and Energy (20154030200610)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Electric Motor Design and Analysis
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Sensorless Control of Electric Motors
- Physical Sciences › Engineering › Control and Systems Engineering › Machine Fault Diagnosis Techniques
- Keywords
- permanent magnet synchronous motor, rotor eccentricity, Hall effect sensors, fault detection, interior permanent magnet synchronous motor, unbalanced magnetic pull, motor vibration, rotor-stator contact, flux measurement
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review