Cited by 2Microgrid Control and OptimizationWind Turbine Control SystemsIslanding Detection in Power Systems

Small-Signal Analysis of Current-Limiting Grid-Forming Inverters

Yang, Bowen, Baeckeland, Nathan, Seo, Gab-Su·2026·IEEE Transactions on Industry Applications

Abstract

Grid-forming (GFM) inverters are equipped with a current limiter to protect the device during grid disturbances. Because the intervention of the current limiter can compromise the transient stability of the GFM inverter, various types of current limiter designs and additional frequency-stabilization control methods have been proposed in recent literature to aid in transient GFM inverter stability; however, the small-signal stability implications of adding these additional control blocks during, in particular, off-nominal conditions are not fully understood. To address this challenge, this paper presents a generic small-signal model of a GFM inverter that incorporates various types of current limiters and frequency stability-enhancing controls. With the proposed model, we analyze the root causes of inverter instability, which reveals two critical design trade-offs. First, due to current-limiter engagement caused by a disturbance, the GFM inverter dynamics are altered, which can lead to voltage oscillations. Second, additional frequency-stabilization controls can improve the small-signal stability of the GFM inverter, but at the cost of reduced power and voltage support to the grid. Comprehensive hardware experiments validate the theoretical concept and analysis. The findings in this work underscore the importance of incorporating both transient-response and small-signal dynamics requirements into the design procedure of GFM current limiters and frequency-stabilization controls.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tia.2026.3655646

Cites

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

The citation lists haven’t been fetched yet

References 40 · Cited by 2

Authors
Yang, B., Baeckeland, N., & Seo, G.-S.
Affiliations
National Laboratory of the Rockies (US)
Venue
IEEE Transactions on Industry Applications
Published
2026-09
Volume
62
Issue
5
Pages
7661-7677
ISSN
  • 0093-9994 (ISSN-L)
  • 1939-9367
OpenAlex
W7125011724
Cited by
2
References
40
Citations by year
2026: 2
FWCI
5.04
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Industry Applications (publishedVersion)
Funders
  • National Laboratory of the Rockies
  • U.S. Department of Energy (DE-AC36-08GO28308)
  • U.S. Department of Energy Office of Energy Efficiency and Renewable Energy
  • Solar Energy Technologies Office Award (38637)
  • Laboratory Directed Research and Development
  • NLR
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Microgrid Control and Optimization
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Wind Turbine Control Systems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Islanding Detection in Power Systems
Keywords
grid-forming inverters, current limiter, small-signal stability, transient stability, voltage oscillations, grid disturbances

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review