Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 602

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Topology Study of Photovoltaic Interface for Maximum Power Point Tracking

Xiao, Weidong, Ozog, Nathan, Dunford, William G.·2007·IEEE Transactions on Industrial Electronics

Abstract

This paper looks at the performance of photovoltaic modules in nonideal conditions and proposes topologies to minimize the degradation of performance caused by these conditions. It is found that the peak power point of a module is significantly decreased due to only the slightest shading of the module, and that this effect is propagated through other nonshaded modules connected in series with the shaded one. Based on this result, two topologies for parallel module connections have been outlined. In addition, dc/dc converter technologies, which are necessary to the design, are compared by way of their dynamic models, frequency characteristics, and component cost. Out of this comparison, a recommendation has been made

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2007.894732

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

See all 602

Metadata

Authors
Xiao, W., Ozog, N., & Dunford, W. G.
Venue
IEEE Transactions on Industrial Electronics
Published
2007-06
Volume
54
Issue
3
Pages
1696-1704
ISSN
1932-4529 (ISSN-L)
OpenAlex
W2163428336
Cited by
602
References
9
FWCI
17.91
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Topology Study of Photovoltaic Interface for Maximum Power Point Tracking. https://app.cochat.ai/papers/10.1109/tie.2007.894732
The paper
Xiao, W., Ozog, N., & Dunford, W. G. (2007). Topology Study of Photovoltaic Interface for Maximum Power Point Tracking. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2007.894732

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.