The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
FPGA-Based Current Controllers for AC Machine Drives—A Review
Abstract
The aim of this paper is to present the interest of implementing digital controllers using field-programmable gate array (FPGA) components. To this purpose, a variety of current control techniques, which is applied to alternating current machine drives, is designed and implemented. They consist of on-off current controllers, proportional-integral current controller, and predictive current controller. The quality of the regulated current is significantly improved. It is mainly due to a very important reduction of the execution time delay. Indeed, in all described techniques, the execution time of the designed hardware architectures is only a few microseconds. This time reduction derives directly from the possibility offered by FPGAs to design very powerful dedicated architectures. Numerous experimental results are given in order to illustrate the efficiency of FPGA-based solutions to achieve high-performance control of electrical systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Modern Power Electronics And Ac Drives
Bose (2005) · Cited by 2,923
Current control techniques for three-phase voltage-source PWM converters: a survey
Kazmierkowski, M. P., & Malesani, L. (1998) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.720325 · Cited by 2,125
Pulsewidth modulation for electronic power conversion
Holtz, J. (1994) · Proceedings of the IEEE · doi:10.1109/5.301684 · Cited by 1,117
Control in Power Electronics: selected problems
Kaźmierkowski, M. P., Krishnan, R., & Blaabjerg, F. (2002) · Cited by 873
Implementation of Hybrid Control for Motor Drives
Lin-Shi, X., Morel, F., Llor, A. M., Allard, B., & Rétif, J.-M. (2007) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2007.898303 · Cited by 106
Tazi, K., Monmasson, É., & Louis, J. (2003) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.1999.819432 · Cited by 38
Cited by
Field programmable gate array-based fault-tolerant hysteresis current control for AC machine drives
Berriri, H., Naouar, W., Bahri, I., Slama-Belkhodja, I., & Monmasson, E. (2012) · IET Electric Power Applications · doi:10.1049/iet-epa.2011.0053 · Cited by 44
Self-citation
Metadata
- Authors
- Naouar, M.-W., Monmasson, E., Naassani, A. A., Slama-Belkhodja, I., & Patin, N.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2007-08
- Volume
- 54
- Issue
- 4
- Pages
- 1907-1925
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2151142962
- Cited by
- 261
- References
- 6
- FWCI
- 27.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: FPGA-Based Current Controllers for AC Machine Drives—A Review. https://app.cochat.ai/papers/10.1109/tie.2007.898302
- The paper
- Naouar, M.-W., Monmasson, E., Naassani, A. A., Slama-Belkhodja, I., & Patin, N. (2007). FPGA-Based Current Controllers for AC Machine Drives—A Review. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2007.898302
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.