The DOI matches its Crossref record.
Flexible Active Power Control of Distributed Power Generation Systems During Grid Faults
Abstract
The increasing penetration of distributed power generation into the power system leads to a continuous evolution of grid interconnection requirements. In particular, active power control will play an important role both during grid faults (low-voltage ride-through capability and controlled current injection) and in normal conditions (reserve function and frequency regulation). The aim of this paper is to propose a flexible active power control based on a fast current controller and a reconfigurable reference current selector. Several strategies to select the current reference are studied and compared using experimental results that are obtained during an unsymmetrical voltage fault. The results of the analysis allow selection of the best reference current in every condition. The proposed methods facilitate multiple choices for fault ride through by simply changing the reference selection criteria.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Opportunities and Challenges of Wireless Sensor Networks in Smart Grid
Gungor, V. C., Lu, B., & Hancke, G. P. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2039455 · Cited by 1,368
Evaluation of Current Controllers for Distributed Power Generation Systems
Timbus, A., Liserre, M., Teodorescu, R., Rodriguez, P., & Blaabjerg, F. (2009) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2009.2012527 · Cited by 934
Self-citationA survey on control of electric power distributed generation systems for microgrid applications
Bouzid, A. M., Guerrero, J. M., Cheriti, A., Bouhamida, M., Sicard, P., & Benghanem, M. (2015) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.01.016 · Cited by 401
Control Strategies Based on Symmetrical Components for Grid-Connected Converters Under Voltage Dips
Alepuz, S., Busquets-Monge, S., Bordonau, J., Martinez-Velasco, J. A., Silva, C. A., Pontt, J., & Rodriguez, J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2017102 · Cited by 373
Building Integrated Photovoltaic System With Energy Storage and Smart Grid Communication
Sechilariu, M., Wang, B., & Locment, F. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222852 · Cited by 332
Metadata
- Authors
- Rodriguez, P., Timbus, A. V., Teodorescu, R., Liserre, M., & Blaabjerg, F.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2007-10
- Volume
- 54
- Issue
- 5
- Pages
- 2583-2592
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2146048275
- Cited by
- 726
- References
- 0
- FWCI
- 45.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Flexible Active Power Control of Distributed Power Generation Systems During Grid Faults. https://app.cochat.ai/papers/10.1109/tie.2007.899914
- The paper
- Rodriguez, P., Timbus, A. V., Teodorescu, R., Liserre, M., & Blaabjerg, F. (2007). Flexible Active Power Control of Distributed Power Generation Systems During Grid Faults. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2007.899914
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.