Low Order PWM Inverter Harmonics Contributions to the Inverter-Fed Induction Machine Fault Diagnosis
Open accessThe DOI matches its Crossref record.
Abstract
In this paper, the effects of inverter harmonics on motor current fault signatures are studied in detail. It is theoretically and experimentally shown that the fault signatures caused by the inverter harmonics are similar and comparable to those generated by the fundamental harmonic on the line current. Theoretically-derived extended relations including bearing fault, eccentricity, and broken rotor bar relations are found to match experimental results. Furthermore, it is observed and reported that the asymmetries on the rotor caused by broken rotor bars increase the amplitude of even harmonics. To confirm these claims, bearing, eccentricity, and broken rotor bar faults are tested and the line current spectrum of each faulty motor is compared with the healthy one. The proposed additional fault data are expected to contribute positively to the inverter-fed motor fault decision making algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
Static-, Dynamic-, and Mixed-Eccentricity Fault Diagnoses in Permanent-Magnet Synchronous Motors
Ebrahimi, B. M., Faiz, J., & Roshtkhari, M. J. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2029577 · Cited by 386
Fault Diagnosis in Industrial Induction Machines Through Discrete Wavelet Transform
Bouzida, A., Touhami, O., Ibtiouen, R., Belouchrani, A., Fadel, M., & Rezzoug, A. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2095391 · Cited by 325
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
Change‐detection algorithm for short‐circuit fault detection in closed‐loop AC drives
Meinguet, F., Semail, E., Kestelyn, X., Mollet, Y., & Gyselinck, J. (2014) · IET Electric Power Applications · doi:10.1049/iet-epa.2012.0316 · Cited by 34
“The most common methods reported in the literature are: current-based techniques [8-16], electromotive force- or voltage-based techniques [17-21], power-based techniques [22] and parameter estimation [23, 24].”
Method
Metadata
- Authors
- Akin, B., Orguner, U., Toliyat, H. A., & Rayner, M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2008
- Volume
- 55
- Issue
- 2
- Pages
- 610-619
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2166219441
- Cited by
- 140
- References
- 0
- FWCI
- 32.08
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Low Order PWM Inverter Harmonics Contributions to the Inverter-Fed Induction Machine Fault Diagnosis. https://app.cochat.ai/papers/10.1109/tie.2007.911954
- The paper
- Akin, B., Orguner, U., Toliyat, H. A., & Rayner, M. (2008). Low Order PWM Inverter Harmonics Contributions to the Inverter-Fed Induction Machine Fault Diagnosis. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2007.911954
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.