The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Sensitivity Study of the Dynamics of Three-Phase Photovoltaic Inverters With an LCL Grid Filter
Open accessAbstract
An accurate small-signal model of three-phase photovoltaic (PV) inverters with a high-order grid filter is derived in this paper. The proposed model takes into account the influence of both the inverter operating point and the PV panel characteristics on the inverter dynamic response. A sensitivity study of the control loops to variations of the dc voltage, PV panel transconductance, supplied power, and grid inductance is performed using the proposed small-signal model. Analytical and experimental results carried out on a 100-kW PV inverter are presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2001) · Springer eBooks · doi:10.1007/b100747 · Cited by 6,112
Fundamentals of Power Electronics
Erickson, R. W., & Maksimović, D. (2020) · Springer eBooks · doi:10.1007/978-3-030-43881-4 · Cited by 5,420
Overview of Control and Grid Synchronization for Distributed Power Generation Systems
Blaabjerg, F., Teodorescu, R., Liserre, M., & Timbus, A. V. (2006) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2006.881997 · Cited by 5,220
Design and Control of an LCL-Filter-Based Three-Phase Active Rectifier
Liserre, M., Blaabjerg, F., & Hansen, S. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2005.853373 · Cited by 2,402
A Variable Step Size INC MPPT Method for PV Systems
Liu, F., Duan, S., Liu, F., Liu, B., & Kang, Y. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.920550 · Cited by 1,313
A phase tracking system for three phase utility interface inverters
Chung, S.-K. (2000) · IEEE Transactions on Power Electronics · doi:10.1109/63.844502 · Cited by 1,192
Liserre, M., Teodorescu, R., & Blaabjerg, F. (2006) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.861185 · Cited by 1,101
Grid current regulation of a three-phase voltage source inverter with an LCL input filter
Twining, E., & Holmes, D. G. (2003) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2003.810838 · Cited by 901
Phase-locked loop techniques. A survey
Hsieh, G.-C., & Hung, J. C. (1996) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.544547 · Cited by 784
Noguchi, T., Togashi, S., & Nakamoto, R. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/41.982265 · Cited by 642
Cited by
Review of Nonisolated High-Step-Up DC/DC Converters in Photovoltaic Grid-Connected Applications
Li, W., & He, X. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049715 · Cited by 1,423
Kanchev, H., Lu, D., Colas, F., Lazarov, V., & Francois, B. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2119451 · Cited by 985
Hossain, M. Z., Rahim, N. A., & Selvaraj, J. A. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.07.017 · Cited by 305
Metadata
- Authors
- Figueres, E., Garcera, G., Sandia, J., Gonzalez-Espin, F., & Rubio, J. C.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-03
- Volume
- 56
- Issue
- 3
- Pages
- 706-717
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2102177496
- Cited by
- 270
- References
- 17
- FWCI
- 24.68
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Sensitivity Study of the Dynamics of Three-Phase Photovoltaic Inverters With an LCL Grid Filter. https://app.cochat.ai/papers/10.1109/tie.2008.2010175
- The paper
- Figueres, E., Garcera, G., Sandia, J., Gonzalez-Espin, F., & Rubio, J. C. (2009). Sensitivity Study of the Dynamics of Three-Phase Photovoltaic Inverters With an LCL Grid Filter. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2008.2010175
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.