Line-Interactive UPS Using a Fuel Cell as the Primary Source
The DOI matches its Crossref record.
Abstract
This paper proposes a line-interactive fuel-cell-powered uninterruptible-power-supply system. A three-port bidirectional converter connects a fuel cell and a supercapacitor to a grid-interfacing inverter. The system can operate in both stand-alone and grid-connected modes. Moreover, an active filtering function is integrated into the system. It is shown that a supercapacitor can serve as both an active and a reactive energy storage and can buffer the periodical low-frequency ripple in the requested power. For connecting the system to the utility grid, a high-performance single-phase phase-locked loop that incorporates an orthogonal filter is presented. Resonant controllers for both the voltage and current regulations eliminate steady-state error and implement selective harmonic compensation. Simulation and experimental results are provided to show the feasibility of the proposed system and the effectiveness of the control methods.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Control Strategy for Flexible Microgrid Based on Parallel Line-Interactive UPS Systems
Guerrero, J. M., Vasquez, J. C., Matas, J., Castilla, M., & de Vicuna, L. G. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009274 · Cited by 788
He, J., & Li, Y. W. (2011) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2011.2168592 · Cited by 759
Vasquez, J. C., Guerrero, J. M., Luna, A., Rodriguez, P., & Teodorescu, R. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2027921 · Cited by 629
Survey on Fault-Tolerant Techniques for Power Electronic Converters
Zhang, W., Xu, D., Enjeti, P. N., Li, H., Hawke, J. T., & Krishnamoorthy, H. S. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2304561 · Cited by 587
Energy management of fuel cell/battery/supercapacitor hybrid power source for vehicle applications
Thounthong, P., Raël, S., & Davat, B. (2009) · Journal of Power Sources · doi:10.1016/j.jpowsour.2008.12.120 · Cited by 574
Energy Storage Technologies for High-Power Applications
Farhadi, M., & Mohammed, O. (2016) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2015.2511096 · Cited by 426
Emergence of hybrid energy storage systems in renewable energy and transport applications – A review
Hemmati, R., & Saboori, H. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.06.029 · Cited by 423
Voltage Support Provided by a Droop-Controlled Multifunctional Inverter
Vasquez, J. C., Mastromauro, R. A., Guerrero, J. M., & Liserre, M. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2015357 · Cited by 326
A High Step-Up Converter With a Voltage Multiplier Module for a Photovoltaic System
Tseng, K.-C., Huang, C.-C., & Shih, W.-Y. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2217157 · Cited by 272
Energy Storage Systems: Technologies and High-Power Applications
Aghmadi, A., & Mohammed, O. A. (2024) · Batteries · doi:10.3390/batteries10040141 · Cited by 264
Analysis of the control strategies for fuel saving in the hydrogen fuel cell vehicles
Hames, Y., Kaya, K., Baltacioglu, E., & Turksoy, A. (2018) · International Journal of Hydrogen Energy · doi:10.1016/j.ijhydene.2017.12.150 · Cited by 259
Zhou, D., Wang, H., & Blaabjerg, F. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2769161 · Cited by 200
“FUEL cells are widely recognized as one of the most promising alternative power conversion technologies due to their high efficiency, and they provide very low pollution [1], [2].”
BackgroundNovel forward–flyback hybrid bidirectional DC–DC converter
Zhang, F., & Yan, Y. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2009561 · Cited by 184
A Nonisolated Interleaved Boost Converter for High-Voltage Gain Applications
Muhammad, M., Armstrong, M., & Elgendy, M. A. (2016) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2015.2488839 · Cited by 179
“Typical examples include electric drives [1], grid-connected inverters [2]–[4], electric vehicle drive trains [5], uninterruptible power supplies system [6], telecommunication power systems, and high-intensity discharge lamps [7].”
BackgroundZhang, Z., Thomsen, O. C., & Andersen, M. A. E. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2011.2134051 · Cited by 102
“With these characteristics, the supercapacitor is a good option to be used in many power conversion systems, such as distributed generation system [3], [4], uninterruptible power supply [5], hybrid electric vehicle [6]–[8], to improve the dynamic performance and stability of the systems.”
MethodNon-isolated bidirectional soft-switching SEPIC/ZETA converter with reduced ripple currents
Song, M.-S., Son, Y.-D., & Lee, K.-H. (2014) · Journal of Power Electronics · doi:10.6113/jpe.2014.14.4.649 · Cited by 56
Metadata
- Authors
- Tao, H., Duarte, J. L., & Hendrix, M. A. M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2008-08
- Volume
- 55
- Issue
- 8
- Pages
- 3012-3021
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2150983941
- Cited by
- 227
- References
- 0
- FWCI
- 38.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.