Doubly Fed Induction Generator Model-Based Sensor Fault Detection and Control Loop Reconfiguration
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Fault tolerance is gaining interest as a means to increase the reliability and availability of distributed energy systems. In this paper, a voltage-oriented doubly fed induction generator, which is often used in wind turbines, is examined. Furthermore, current, voltage, and position sensor fault detection, isolation, and reconfiguration are presented. Machine operation is not interrupted. A bank of observers provides residuals for fault detection and replacement signals for the reconfiguration. Control is temporarily switched from closed loop into open-loop to decouple the drive from faulty sensor readings. During a short period of open-loop operation, the fault is isolated using parity equations. Replacement signals from observers are used to reconfigure the drive and reenter closed-loop control. There are no large transients in the current. Measurement results and stability analysis show good results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jeong, Y.-S., Sul, S.-K., Schulz, S. E., & Patel, N. R. (2005) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2004.840947 · Cited by 240 · cited 1×
“Sensor fault-tolerant control for electric vehicles has also been treated [16], [17], [19], [39].”
Background
Cited by
Overview of Multi-MW Wind Turbines and Wind Parks
Liserre, M., Cardenas, R., Molinas, M., & Rodriguez, J. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2103910 · Cited by 876
Real-Time Implementation of Fault-Tolerant Control Systems With Performance Optimization
Yin, S., Luo, H., & Ding, S. X. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2273477 · Cited by 644
A Survey on Wind Turbine Condition Monitoring and Fault Diagnosis—Part I: Components and Subsystems
Qiao, W., & Lu, D. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2422112 · Cited by 533
Foo, G. H. B., Zhang, X., & Vilathgamuwa, D. M. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2244537 · Cited by 369
Jlassi, I., Estima, J. O., El Khil, S. K., Bellaaj, N. M., & Cardoso, A. J. M. (2017) · IEEE Transactions on Industry Applications · doi:10.1109/tia.2016.2616398 · Cited by 284
“Luenberger observers are used in [39] and [40] to provide residuals for fault diagnosis.”
BackgroundMethod
Metadata
- Authors
- Rothenhagen, K., & Fuchs, F. W.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-10
- Volume
- 56
- Issue
- 10
- Pages
- 4229-4238
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2100614885
- Cited by
- 157
- References
- 1
- FWCI
- 21.18
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.