The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fault Detection on Multicell Converter Based on Output Voltage Frequency Analysis
Open accessAbstract
Multilevel converters use a large amount of semiconductors, allowing the reconfigurate of the converter to work even on internal fault condition. This paper presents a method to detect faulty cells in a cascaded multicell converter requiring just one voltage measurement per output phase. The method is based on high-frequency harmonic analysis, using a dynamic prediction of their behavior, avoiding erroneous detection on transients while keeping the precision under real fault events. Once the faulty cell is detected, it can be bypassed allowing the converter to keep working according to previously reported techniques. Experimental results confirm accurate and fast fault detection, with a good rejection to normal operation transients.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
High‐Power Converters and AC Drives
Wu, B., & Narimani, M. (2017) · doi:10.1002/9781119156079 · Cited by 1,571
Cited by
Multilevel Converters: An Enabling Technology for High-Power Applications
Rodriguez, J., Franquelo, L. G., Kouro, S., Leon, J. I., Portillo, R. C., Prats, M. A. M., & Perez, M. A. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2030235 · Cited by 1,196
Self-citationSurvey on Reliability of Power Electronic Systems
Song, Y., & Wang, B. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2192503 · Cited by 861
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440
Survey on Fault Operation on Multilevel Inverters
Lezana, P., Pou, J., Meynard, T. A., Rodriguez, J., Ceballos, S., & Richardeau, F. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032194 · Cited by 384
Self-citationFault Detection for Modular Multilevel Converters Based on Sliding Mode Observer
Shao, S., Wheeler, P. W., Clare, J. C., & Watson, A. J. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2242093 · Cited by 361
Metadata
- Authors
- Lezana, P., Aguilera, R., & Rodriguez, J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-06
- Volume
- 56
- Issue
- 6
- Pages
- 2275-2283
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2161004549
- Cited by
- 215
- References
- 1
- FWCI
- 7.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fault Detection on Multicell Converter Based on Output Voltage Frequency Analysis. https://app.cochat.ai/papers/10.1109/tie.2009.2013845
- The paper
- Lezana, P., Aguilera, R., & Rodriguez, J. (2009). Fault Detection on Multicell Converter Based on Output Voltage Frequency Analysis. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2009.2013845
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.