The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Classification of Energy Consumption in Buildings With Outlier Detection
Abstract
In this paper, we propose an intelligent data-analysis method for modeling and prediction of daily electricity consumption in buildings. The objective is to enable a building-management system to be used for forecasting and detection of abnormal energy use. First, an outlier-detection method is proposed to identify abnormally high or low energy use in a building. Then a canonical variate analysis is employed to describe latent variables of daily electricity-consumption profiles, which can be used to group the data sets into different clusters. Finally, a simple classifier is used to predict the daily electricity-consumption profiles. A case study, based on a mixed-use environment, was studied. The results demonstrate that the method proposed in this paper can be used in conjunction with a building-management system to identify abnormal utility consumption and notify building operators in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A review on buildings energy consumption information
Pérez-Lombard, L., Ortiz, J., & Pout, C. (2008) · Energy and Buildings · doi:10.1016/j.enbuild.2007.03.007 · Cited by 6,649
Cited by
Review of Smart Meter Data Analytics: Applications, Methodologies, and Challenges
Wang, Y., Chen, Q., Hong, T., & Kang, C. (2019) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2018.2818167 · Cited by 1,369
Fan, C., Xiao, F., & Wang, S. (2014) · Applied Energy · doi:10.1016/j.apenergy.2014.04.016 · Cited by 565
Overview and performance assessment of the clustering methods for electrical load pattern grouping
Chicco, G. (2012) · Energy · doi:10.1016/j.energy.2011.12.031 · Cited by 484
Machine learning for estimation of building energy consumption and performance: a review
Seyedzadeh, S., Rahimian, F. P., Glesk, I., & Roper, M. (2018) · Visualization in Engineering · doi:10.1186/s40327-018-0064-7 · Cited by 482
Digital twin-enabled anomaly detection for built asset monitoring in operation and maintenance
Lu, Q., Xie, X., Parlikad, A. K., & Schooling, J. M. (2020) · Automation in Construction · doi:10.1016/j.autcon.2020.103277 · Cited by 481
Metadata
- Authors
- Li, X., Bowers, C. P., & Schnier, T.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2010-11
- Volume
- 57
- Issue
- 11
- Pages
- 3639-3644
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2167152259
- Cited by
- 210
- References
- 1
- FWCI
- 17.31
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Classification of Energy Consumption in Buildings With Outlier Detection. https://app.cochat.ai/papers/10.1109/tie.2009.2027926
- The paper
- Li, X., Bowers, C. P., & Schnier, T. (2010). Classification of Energy Consumption in Buildings With Outlier Detection. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2009.2027926
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.