The DOI matches its Crossref record.
Online and Remote Motor Energy Monitoring and Fault Diagnostics Using Wireless Sensor Networks
Abstract
This paper identifies the synergies between wireless sensor networks (WSNs) and nonintrusive electrical-signal-based motor signature analysis and proposes a scheme of applying WSNs in online and remote energy monitoring and fault diagnostics for industrial motor systems. The main scope is to provide a system overview where the nonintrusive nature of the electrical-signal-based motor signature analysis enables its applications in a WSN architecture. Special considerations in designing nonintrusive motor energy monitoring and fault diagnostic methods in such systems are discussed. This paper also provides detailed analyses to address the real-world challenges in designing and deploying WSNs in practice, including wireless-link-quality dynamics, noise and interference, and environmental impact on communication range and reliability. The overall system feasibility is investigated through a series of laboratory experiments and field tests. First, the concept of a remote and online energy monitoring and fault diagnostic system is demonstrated using a simplified star-type IEEE 802.15.4 compliant WSN in the laboratory. Two well-established nonintrusive motor diagnostic algorithms are intentionally used to prove the feasibility. Next, the challenges of applying the proposed WSN scheme in real industrial environments are analyzed experimentally using field test results.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smart Grid Technologies: Communication Technologies and Standards
Gungor, V. C., Sahin, D., Kocak, T., Ergut, S., Buccella, C., Cecati, C., & Hancke, G. P. (2011) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2011.2166794 · Cited by 2,688
Self-citationOpportunities and Challenges of Wireless Sensor Networks in Smart Grid
Gungor, V. C., Lu, B., & Hancke, G. P. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2039455 · Cited by 1,368
Self-citationA survey on wireless sensor networks for smart grid
Fadel, E., Gungor, V. C., Nassef, L., Akkari, N., Malik, M. G. A., Almasri, S., & Akyildiz, I. F. (2015) · Computer Communications · doi:10.1016/j.comcom.2015.09.006 · Cited by 328
Self-citationA fog computing-based framework for process monitoring and prognosis in cyber-manufacturing
Wu, D., Liu, S., Zhang, L., Terpenny, J., Gao, R. X., Kurfess, T., & Guzzo, J. A. (2017) · Journal of Manufacturing Systems · doi:10.1016/j.jmsy.2017.02.011 · Cited by 287
Smet, V., Forest, F., Huselstein, J.-J., Rashed, A., & Richardeau, F. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2196894 · Cited by 232
Metadata
- Authors
- Lu, B., & Gungor, V. C.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2009-11
- Volume
- 56
- Issue
- 11
- Pages
- 4651-4659
- ISSN
- 0278-0046 (ISSN-L)
- OpenAlex
- W2114402558
- Cited by
- 201
- References
- 0
- FWCI
- 30.09
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Online and Remote Motor Energy Monitoring and Fault Diagnostics Using Wireless Sensor Networks. https://app.cochat.ai/papers/10.1109/tie.2009.2028349
- The paper
- Lu, B., & Gungor, V. C. (2009). Online and Remote Motor Energy Monitoring and Fault Diagnostics Using Wireless Sensor Networks. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2009.2028349
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.