CoChat

Implementation of a Transformerless Common-Mode Active Filter for Offline Converter Systems

Heldwein, Marcelo Lobo, Ertl, Hans, Biela, Juergen, Kolar, Johann W · 2010 · IEEE Transactions on Industrial Electronics

The DOI matches its Crossref record; 19 of the 24 references it cites were found in a registry or an index.

Abstract

This paper presents a study and practical implementation of an active filter employing a high-frequency (HF) power amplifier and passive-filter components to be connected to the ac power lines in order to mitigate common-mode conducted emissions of three-phase pulsewidth modulation converter systems. The filter topology is chosen from different possibilities listed in a literature survey and studied regarding practical implementation issues, where requirements for an HF power amplifier to be applied in active filtering are derived. Special attention is put on the stability analysis where the challenges for the feedback are discussed, and a simple feedback structure is proposed. Other feedback concepts are analyzed, and limitations posed by stability requirements are presented. A prototype is designed and built, from which mathematical and experimental results are obtained demonstrating the potential and limitations of such a system.

Overview

Integrity signals

Registry

Crossref · 10.1109/tie.2009.2032204

Cites

19 of 19 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Citations

Cites

Show all 19 references

Research works printed but not linked: 10

  1. 2004, Active common mode filter connected in A-C line
  2. 2001, Noise filter
  3. 2004, Active EMI filter having no inductive current sensing device
  4. 2004, Active EMI filter
  5. zhu, 1999, design and evaluation if an active ripple filter with rogowski-coil current sensing, Proc IEEE Power Electron Spec Conf, 2, 874
  6. 2007, RFI capacitors for the AC line (X and Y capacitors)
  7. 2003, Active filter
  8. 1998, Hybrid active power filter with programmed impedance characteristics
  9. 2003, Active filter for reduction of common mode current
  10. 1977, C I S P R Specification for Radio Interference Measuring Apparatus and Measurement MethodsPublication 16

Cited by

Metadata

Authors
Heldwein, M. L., Ertl, H., Biela, J., & Kolar, J. W.
Affiliations
  • Universidade Federal de Santa Catarina (BR)
  • TU Wien (AT)
  • ETH Zurich (CH)
Venue
IEEE Transactions on Industrial Electronics
Published
2010-05
Volume
57
Issue
5
Pages
1772-1786
ISSN
0278-0046 (ISSN-L)
OpenAlex
W2150599959
Cited by
90
References
24
Citations by year
2026: 11 · 2025: 2 · 2024: 5 · 2023: 7 · 2022: 4 · 2021: 7 · 2020: 5 · 2019: 7 · 2018: 6 · 2017: 4 · 2016: 6 · 2015: 8 · 2014: 2 · 2013: 4 · 2012: 5
FWCI
3.17
Type
journal article
Language
en
Open access
closed
Locations
IEEE Transactions on Industrial Electronics (publishedVersion)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Electromagnetic Compatibility and Noise Suppression
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Power Quality and Harmonics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
Keywords
high-frequency power amplifiers

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.