A Novel Improved Variable Step-Size Incremental-Resistance MPPT Method for PV Systems
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
Maximum power point (MPP) tracking (MPPT) techniques are widely applied in photovoltaic (PV) systems to make PV array generate peak power which depends on solar irradiation. Among all the MPPT strategies, the incremental-conductance (INC) algorithm is widely employed due to easy implementation and high tracking accuracy. In this paper, a novel variable step-size incremental-resistance MPPT algorithm is introduced, which not only has the merits of INC but also automatically adjusts the step size to track the PV array MPP. Compared with the variable step-size INC method, the proposed scheme can greatly improve the MPPT response speed and accuracy at steady state simultaneously. Moreover, it is more suitable for practical operating conditions due to a wider operating range. This paper provides the theoretical analysis and the design principle of the proposed MPPT strategy. Simulation and experimental results verify its feasibility.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Comparison of Photovoltaic Array Maximum Power Point Tracking Techniques
Esram, T., & Chapman, P. L. (2007) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2006.874230 · Cited by 5,425
Optimization of Perturb and Observe Maximum Power Point Tracking Method
Femia, N., Petrone, G., Spagnuolo, G., & Vitelli, M. (2005) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2005.850975 · Cited by 3,002
Maximum photovoltaic power tracking: an algorithm for rapidly changing atmospheric conditions
Hussein, K. H. (1995) · IEE Proceedings - Generation, Transmission and Distribution · doi:10.1049/ip-gtd:19951577 · Cited by 1,764
Development of a microcontroller-based, photovoltaic maximum power point tracking control system
Koutroulis, E., Kalaitzakis, K. C., & Voulgaris, N. C. (2001) · IEEE Transactions on Power Electronics · doi:10.1109/63.903988 · Cited by 1,417
A Variable Step Size INC MPPT Method for PV Systems
Liu, F., Duan, S., Liu, F., Liu, B., & Kang, Y. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.920550 · Cited by 1,313
A modified adaptive hill climbing MPPT method for photovoltaic power systems
Xiao, W., & Dunford, W. G. (2004) · 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551) · doi:10.1109/pesc.2004.1355417 · Cited by 728
Reliability Issues in Photovoltaic Power Processing Systems
Petrone, G., Spagnuolo, G., Teodorescu, R., Veerachary, M., & Vitelli, M. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.924016 · Cited by 579
DSP-based multiple peak power tracking for expandable power system
Wu, W., Pongratananukul, N., Qiu, W., Rustom, K., Kasparis, T., & Batarseh, I. (2003) · Eighteenth Annual IEEE Applied Power Electronics Conference and Exposition, 2003. APEC '03. · doi:10.1109/apec.2003.1179263 · Cited by 168
A novel optimum operating point tracker of the solar cell power supply system
Kobayashi, K., Matsuo, H., & Sekine, Y. (2005) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/pesc.2004.1355451 · Cited by 143
Prediction-data-based maximum-power-point-tracking method for photovoltaic power generation systems
Mutoh, N., Matuo, T., Okada, K., & Sakai, M. (2003) · IEEE Power Electronics Specialists Conference (PESC) · doi:10.1109/psec.2002.1022386 · Cited by 114
Finding an optimal PV panel maximum power point tracking method
Bekker, B., & Beukes, H. J. (2005) · IEEE AFRICON · doi:10.1109/africon.2004.1406864 · Cited by 107
Photo-voltaic power converter with a simple maximum-power-point-tracker
Yuvarajan, S., & Xu, S. (2003) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2003.1205040 · Cited by 103
Fuzzy system based maximum power point tracking for PV system
Wilamowski, B. M., & Li, X. (2003) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2002.1182924 · Cited by 97
Khaehintung, N., Pramotung, K., Tuvirat, B., & Sirisuk, P. (2005) · Annual Conference of the IEEE Industrial Electronics Society (IECON) · doi:10.1109/iecon.2004.1432228 · Cited by 96
A research on photovoltaic energy controlling system with maximum power point tracking
Sun, X., Wu, W., Li, X., & Zhao, Q. (2003) · Power Conversion Conference · doi:10.1109/pcc.2002.997626 · Cited by 80
Development of a MPPT method for photovoltaic systems
Tafticht, T., & Agbossou, K. (2004) · Conference proceedings - Canadian Conference on Electrical and Computer Engineering · doi:10.1109/ccece.2004.1345317 · Cited by 71
Tan, C. W., Green, T. C., & Hernandez-Aramburo, C. A. (2006) · doi:10.1109/peds.2005.1619736 · Cited by 67
Hussein, A., Hirasawa, K., Hu, J., & Murata, J. (2003) · International Joint Conference on Neural Networks (IJCNN) · doi:10.1109/ijcnn.2002.1005541 · Cited by 50
Cited by
Reza Reisi, A., Hassan Moradi, M., & Jamasb, S. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.11.052 · Cited by 690
“The incremental conductance (IncCond) method employs the slope of the PV array power characteristics to track MPP [62–68].”
MethodIshaque, K., & Salam, Z. (2013) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2012.11.032 · Cited by 600
Control and Circuit Techniques to Mitigate Partial Shading Effects in Photovoltaic Arrays
Bidram, A., Davoudi, A., & Balog, R. S. (2012) · IEEE Journal of Photovoltaics · doi:10.1109/jphotov.2012.2202879 · Cited by 493
MPPT methods for solar PV systems: a critical review based on tracking nature
Podder, A. K., Roy, N. K., & Pota, H. R. (2019) · IET Renewable Power Generation · doi:10.1049/iet-rpg.2018.5946 · Cited by 425
Maximum power point tracking (MPPT) techniques: Recapitulation in solar photovoltaic systems
Verma, D., Nema, S., Shandilya, A. M., & Dash, S. K. (2016) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2015.10.068 · Cited by 420
Metadata
- Authors
- Mei, Q., Shan, M., Liu, L., & Guerrero, J. M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-06
- Volume
- 58
- Issue
- 6
- Pages
- 2427-2434
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2099486275
- Cited by
- 637
- References
- 18
- FWCI
- 14.38
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.