An Impedance Identification Approach to Sensitive Detection and Location of Stator Turn-to-Turn Faults in a Closed-Loop Multiple-Motor Drive
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A single closed-loop inverter drive with multiple motors connected to it is a type of drive topology commonly used in steel processing industry, electric railway systems, and electric vehicles. However, condition monitoring for this type of drive configuration remains largely unexplored. This paper proposes an impedance identification approach to detect and locate the stator turn-to-turn fault in a multiple-motor drive system. Sensitive and fast fault detection is achieved by utilizing the characteristics of current regulators in the motor controller. Experimental results show that the proposed method can reliably detect and locate the stator turn fault on two shaft-coupled 5-hp induction machines under different operating conditions and fault levels with no need of any machine parameters. Although originally developed for multiple-motor drives, the detection scheme can also be directly applied to most of the conventional closed-loop induction motor drives.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Advances in Diagnostic Techniques for Induction Machines
Bellini, A., Filippetti, F., Tassoni, C., & Capolino, G.-A. (2008) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2008.2007527 · Cited by 1,140
Cited by
Riera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
Recent Advances in Modeling and Online Detection of Stator Interturn Faults in Electrical Motors
Gandhi, A., Corrigan, T., & Parsa, L. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2089937 · Cited by 544
Sarikhani, A., & Mohammed, O. A. (2013) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2222857 · Cited by 177
“However, for the real-time implementation, the aforementioned approach suffers from issues such as obtaining the characteristics of the healthy motor drive, compensation for dc voltage variation, and accounting for various inverter nonideal behaviors [14].”
BackgroundMethodMitigation of Turn-to-Turn Faults in Fault Tolerant Permanent Magnet Synchronous Motors
Cintron-Rivera, J. G., Foster, S. N., & Strangas, E. G. (2015) · IEEE Transactions on Energy Conversion · doi:10.1109/tec.2014.2360813 · Cited by 104
“A winding fault creates an unbalanced operating condition, from which measurable information such as the voltages [19], [20], sequence components [21], impedance changes [22] and harmonic content [12] could be used for detection purposes.”
Synchronous Demodulation of Control Voltages for Stator Interturn Fault Detection in PMSM
Boileau, T., Leboeuf, N., Nahid-Mobarakeh, B., & Meibody-Tabar, F. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2254132 · Cited by 90
“Other approaches based on estimation of direct and inverse impedances are proposed [21].”
Background
Metadata
- Authors
- Cheng, S., Zhang, P., & Habetler, T. G.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-05
- Volume
- 58
- Issue
- 5
- Pages
- 1545-1554
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2104988213
- Cited by
- 149
- References
- 1
- FWCI
- 16.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Impedance Identification Approach to Sensitive Detection and Location of Stator Turn-to-Turn Faults in a Closed-Loop Multiple-Motor Drive. https://app.cochat.ai/papers/10.1109/tie.2010.2064276
- The paper
- Cheng, S., Zhang, P., & Habetler, T. G. (2011). An Impedance Identification Approach to Sensitive Detection and Location of Stator Turn-to-Turn Faults in a Closed-Loop Multiple-Motor Drive. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2010.2064276
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.