The DOI matches its Crossref record.
Faulty Operations of a PM Fractional-Slot Machine With a Dual Three-Phase Winding
Abstract
The permanent-magnet (PM) machine with dual three-phase windings is proposed for applications requiring continuous operating even under a partial fault. The two windings are supplied by two separate inverters. Thus, in the event of a fault of one winding, this is disconnected, and the machine continues to be operated by means of the healthy winding. This paper investigates the PM machine with dual three-phase windings and its capabilities during faulty operating conditions. A fractional-slot interior PM machine with 12 slots and 10 poles is taken into account. Its performance is investigated according to different winding configurations. The torque behavior, overload capability, and thermal limits are evaluated under open-circuit and short-circuit faults. A finite-element analysis as well as experimental tests is carried out on a prototype of such a machine.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part I
Barrero, F., & Duran, M. J. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2447733 · Cited by 927
Recent Advances in the Design, Modeling, and Control of Multiphase Machines—Part II
Duran, M. J., & Barrero, F. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2448211 · Cited by 658
Jiang, Y., Zhang, Z., Jiang, W., Geng, W., & Huang, J. (2018) · IET Electric Power Applications · doi:10.1049/iet-epa.2017.0754 · Cited by 45
Change‐detection algorithm for short‐circuit fault detection in closed‐loop AC drives
Meinguet, F., Semail, E., Kestelyn, X., Mollet, Y., & Gyselinck, J. (2014) · IET Electric Power Applications · doi:10.1049/iet-epa.2012.0316 · Cited by 34
“A reconfiguration of the drive to mitigate the fault propagation is also an alternative, assuming the drive is fault-tolerant to short-circuit faults [31-38].”
BackgroundDieterle, O., Greiner, T., & Heidrich, P. (2019) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2018.2835422 · Cited by 25
“This method, which is often called an active or symmetric SC (SSC), leads to a symmetrical state and, therewith, reduces the torque ripple, while there is a constant breaking torque with speeddependent magnitude now [19]–[21].”
BackgroundMethodInfluential
Metadata
- Authors
- Barcaro, M., Bianchi, N., & Magnussen, F.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-09
- Volume
- 58
- Issue
- 9
- Pages
- 3825-3832
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2144869573
- Cited by
- 170
- References
- 0
- FWCI
- 2.99
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Faulty Operations of a PM Fractional-Slot Machine With a Dual Three-Phase Winding. https://app.cochat.ai/papers/10.1109/tie.2010.2087300
- The paper
- Barcaro, M., Bianchi, N., & Magnussen, F. (2011). Faulty Operations of a PM Fractional-Slot Machine With a Dual Three-Phase Winding. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2010.2087300
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.