The DOI matches its Crossref record.
Unbalanced Three-Phase Optimal Power Flow for Smart Grids
Abstract
Advanced distribution management system (DMS), an evolution of supervisory control and data acquisition obtained by extending its working principles from transmission to distribution, is the brain of a smart grid. Advanced DMS assesses smart functions in the distribution system and is also responsible for assessing control functions such as reactive dispatch, voltage regulation, contingency analysis, capability maximization, or line switching. Optimal power flow (OPF)-based tools can be suitably adapted to the requirements of smart distribution network and be employed in an advanced DMS framework. In this paper, the authors present a methodology for unbalanced three-phase OPF (TOPF) for DMS in a smart grid. In the formulation of the TOPF, control variables of the optimization problem are actual active load demand and reactive power outputs of microgenerators. The TOPF is based on a quasi-Newton method and makes use of an open-source three-phase unbalanced distribution load flow. Test results are presented on the IEEE 123-bus Radial Distribution Feeder test case.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
A Survey on Smart Grid Potential Applications and Communication Requirements
Gungor, V. C., Sahin, D., Kocak, T., Ergut, S., Buccella, C., Cecati, C., & Hancke, G. P. (2013) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2012.2218253 · Cited by 1,115
Distributed Optimal Power Flow for Smart Microgrids
Dall'Anese, E., Zhu, H., & Giannakis, G. B. (2013) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2013.2248175 · Cited by 679
Das, C. K., Bass, O., Kothapalli, G., Mahmoud, T. S., & Habibi, D. (2018) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2018.03.068 · Cited by 656
Savaghebi, M., Jalilian, A., Vasquez, J. C., & Guerrero, J. M. (2012) · IEEE Transactions on Smart Grid · doi:10.1109/tsg.2011.2181432 · Cited by 475
Local flexibility markets: Literature review on concepts, models and clearing methods
Jin, X., Wu, Q., & Jia, H. (2020) · Applied Energy · doi:10.1016/j.apenergy.2019.114387 · Cited by 373
Distributed Energy Trading: The Multiple-Microgrid Case
Gregoratti, D., & Matamoros, J. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2352592 · Cited by 310
A review of optimal power flow studies applied to smart grids and microgrids
Abdi, H., Beigvand, S. D., & Scala, M. L. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2016.12.102 · Cited by 254
Details and implementation of a SiC-based solid state transformer prototype
Ramirez, J. M., Barrios, R. A., & Salome, B. J. (2017) · 2017 IEEE PES Innovative Smart Grid Technologies Conference - Latin America (ISGT Latin America) · doi:10.1109/isgt-la.2017.8126690 · Cited by 6
“They should also allow bidirectional power flow, to accommodate the integration of distributed generation [19].”
Background
Metadata
- Authors
- Bruno, S., Lamonaca, S., Rotondo, G., Stecchi, U., & La Scala, M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2011-10
- Volume
- 58
- Issue
- 10
- Pages
- 4504-4513
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W1963539491
- Cited by
- 161
- References
- 0
- FWCI
- 9.36
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.