Open- and Short-Circuit Switch Fault Diagnosis for Nonisolated DC–DC Converters Using Field Programmable Gate Array

Open access
Shahbazi, M., Jamshidpour, E., Poure, P., Saadate, S., Zolghadri, M. R. · 2013 · IEEE Transactions on Industrial Electronics

Abstract

Fault detection (FD) in power electronic converters is necessary in embedded and safety critical applications to prevent further damage. Fast FD is a mandatory step in order to make a suitable response to a fault in one of the semiconductor devices. The aim of this study is to present a fast yet robust method for fault diagnosis in nonisolated dc-dc converters. FD is based on time and current criteria which observe the slope of the inductor current over the time. It is realized by using a hybrid structure via coordinated operation of two FD subsystems that work in parallel. No additional sensors, which increase system cost and reduce reliability, are required for this detection method. For validation, computer simulations are first carried out. The proposed detection scheme is validated on a boost converter. Effects of input disturbances and the closed-loop control are also considered. In the experimental setup, a field programmable gate array digital target is used for the implementation of the proposed method, to perform a very fast switch FD. Results show that, with the presented method, FD is robust and can be done in a few microseconds.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tie.2012.2224078

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 195

Metadata

Authors
Shahbazi, M., Jamshidpour, E., Poure, P., Saadate, S., & Zolghadri, M. R.
Venue
IEEE Transactions on Industrial Electronics
Published
2013-09
Volume
60
Issue
9
Pages
4136-4146
ISSN
  • 0278-0046 (ISSN-L)
  • 1557-9948
OpenAlex
W2012756905
Cited by
195
References
1
FWCI
7.53
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Open- and Short-Circuit Switch Fault Diagnosis for Nonisolated DC–DC Converters Using Field Programmable Gate Array. https://app.cochat.ai/papers/10.1109/tie.2012.2224078
The paper
Shahbazi, M., Jamshidpour, E., Poure, P., Saadate, S., & Zolghadri, M. R. (2013). Open- and Short-Circuit Switch Fault Diagnosis for Nonisolated DC–DC Converters Using Field Programmable Gate Array. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2012.2224078

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.