Stator-Current Spectrum Signature of Healthy Cage Rotor Induction Machines
The DOI matches its Crossref record.
Abstract
Before applying current-signature-analysis-based monitoring methods, it is necessary to thoroughly analyze the existence of the various harmonics on healthy machines. As such an analysis is only done in very few papers, the objective of this paper is to make a clear and rigorous characterization and classification of the harmonics present in a healthy cage rotor induction motor spectrum as a starting point for diagnosis. Magnetomotive force space harmonics, slot permeance harmonics, and saturation of main magnetic flux path through the virtual air-gap permeance variation are taken into analytical consideration. General rules are introduced giving a connection between the number of stator slots, rotor bars, and pole pairs and the existence of rotor slot harmonics as well as saturation-related harmonics in the current spectrum. For certain combinations of stator and rotor slots, saturation-related harmonics are shown to be most prominent in motors with a pole pair number of two or more. A comparison of predicted and measured current harmonics is given for several motors with different numbers of pole pairs, stator slots, and rotor bars.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135
“Recent development of current-based spectrum signature analysis for fault diagnosis can be found in [156] and [157].”
BackgroundRiera-Guasp, M., Antonino-Daviu, J. A., & Capolino, G.-A. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2375853 · Cited by 573
A Review of Fault Detection and Diagnosis for the Traction System in High-Speed Trains
Chen, H., & Jiang, B. (2020) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2019.2897583 · Cited by 413
Giantomassi, A., Ferracuti, F., Iarlori, S., Ippoliti, G., & Longhi, S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2370936 · Cited by 168
“Another issue regarding the current signature is the rigorous characterization and classification of healthy IM [10].”
BackgroundBurriel-Valencia, J., Puche-Panadero, R., Martinez-Roman, J., Sapena-Bano, A., & Pineda-Sanchez, M. (2017) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2016.2647458 · Cited by 144
“Additionally, the diagnostic procedure must be sim ple, compact and fast, to be executed on-line by embedded devices [6], [7], [12], or even by the same devices that control the IM , such as variable speed drives (VSDs).”
BackgroundMethod
Metadata
- Authors
- Joksimovic, G. M., Riger, J., Wolbank, T. M., Peric, N., & Vasak, M.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2013-09
- Volume
- 60
- Issue
- 9
- Pages
- 4025-4033
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W1991907411
- Cited by
- 125
- References
- 0
- FWCI
- 12.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Stator-Current Spectrum Signature of Healthy Cage Rotor Induction Machines. https://app.cochat.ai/papers/10.1109/tie.2012.2236995
- The paper
- Joksimovic, G. M., Riger, J., Wolbank, T. M., Peric, N., & Vasak, M. (2013). Stator-Current Spectrum Signature of Healthy Cage Rotor Induction Machines. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2012.2236995
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.