A Fault-Tolerant Single-Phase Five-Level Inverter for Grid-Independent PV Systems
The DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
In this paper, a fault-tolerant single-phase five-level inverter configuration is proposed for photovoltaic (PV) generation systems. Conventional two-level inverters are popularly used in PV applications, but these inverters provide the output voltage with considerable harmonic content. One of the efficient ways to improve the power quality of PV generation systems is to replace a two-level inverter with a multilevel inverter. Conventional multilevel inverters reduce total harmonic distortion and filter requirements effectively, but it has limitations in terms of reliability due to increased device count and capacitor voltage balancing issues. Therefore, a fault-tolerant single-phase five-level inverter is presented, which is constructed by using a half-bridge two-level inverter, a three-level diode clamp inverter, and a bidirectional switch. The proposed inverter topology can tolerate the system faults due to failure of the source and/or switching devices with least modification in the switching combinations. It has less number of switching devices compared to conventional five-level inverters. The topology also has the energy-balancing capability between sources which helps in reducing uneven charge of batteries in case of partial shading or hotspots on one side of the PV panels. The proposed system under normal and faulty condition is simulated in MATLAB/Simulink environment, and results are verified with a laboratory prototype.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Multilevel inverters: a survey of topologies, controls, and applications
Rodriguez, J., Lai, J.-S., & Peng, F. Z. (2002) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2002.801052 · Cited by 6,715 · cited 1×
“Conventional multilevel inverters are introduced in [7] and [8], which reduce filter size requirement and improve power quality of PV generation systems by reducing total harmonic distortion.”
BackgroundMultilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (2002) · IAS '95. Conference Record of the 1995 IEEE Industry Applications Conference Thirtieth IAS Annual Meeting · doi:10.1109/ias.1995.530601 · Cited by 2,665 · cited 1×
“Conventional multilevel inverters are introduced in [7] and [8], which reduce filter size requirement and improve power quality of PV generation systems by reducing total harmonic distortion.”
BackgroundMultilevel converters-a new breed of power converters
Lai, J.-S., & Peng, F. Z. (1996) · IEEE Transactions on Industry Applications · doi:10.1109/28.502161 · Cited by 2,604
Evaluation of the Main MPPT Techniques for Photovoltaic Applications
de Brito, M. A. G., Galotto, L., Sampaio, L. P., Melo, G. D. A. E., & Canesin, C. A. (2012) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2012.2198036 · Cited by 1,678 · cited 1×
“The maximum power is tracked using the perturb and observe algorithm given in [22]”
MethodBabaei, E., Laali, S., & Bayat, Z. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2336601 · Cited by 523
Survey of fault-tolerance techniques for three-phase voltage source inverters
Mirafzal, B. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2014.2301712 · Cited by 440 · cited 1×
“The survey of fault-tolerant techniques for three-phase two-level and multilevel inverters is discussed in [18] and [19].”
BackgroundA Novel Multilevel Inverter Based on Switched DC Sources
Gupta, K. K., & Jain, S. (2014) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2013.2282606 · Cited by 435 · cited 1×
“By addressing some of the aforementioned issues, many multilevel inverter topologies are presented in literature with reduced number of devices for PV generation systems and drive applications [10]–[14].”
BackgroundSurvey on Fault Operation on Multilevel Inverters
Lezana, P., Pou, J., Meynard, T. A., Rodriguez, J., Ceballos, S., & Richardeau, F. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2032194 · Cited by 384 · cited 1×
“The survey of fault-tolerant techniques for three-phase two-level and multilevel inverters is discussed in [18] and [19].”
BackgroundMultistring Five-Level Inverter With Novel PWM Control Scheme for PV Application
Rahim, N. A., & Selvaraj, J. A.-L. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2034683 · Cited by 320
Reliability Improvement of a T-Type Three-Level Inverter With Fault-Tolerant Control Strategy
Choi, U.-M., Blaabjerg, F., & Lee, K.-B. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2325891 · Cited by 258 · cited 3×
“The previously discussed topologies [16]–[20] with single or multiple sources”
Background
Cited by
Prabaharan, N., & Palanisamy, K. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.03.121 · Cited by 302
Reviews on multilevel converter and modulation techniques
Hasan, N. S., Rosmin, N., Osman, D. A. A., & Musta’amal@Jamal, A. H. (2017) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2017.05.163 · Cited by 178
Metadata
- Authors
- A, M. R., & Sivakumar, K.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2015-12
- Volume
- 62
- Issue
- 12
- Pages
- 7569-7577
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W1999537226
- Cited by
- 219
- References
- 18
- FWCI
- 8.98
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.