Operating Principle and Performance Optimization of a Three-Level NPC Dual-Active-Bridge DC–DC Converter
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Aiming to improve the performance features of conventional two-level dual-active-bridge (DAB) converters, this paper presents a three-level neutral-point-clamped (NPC) DAB dc-dc converter. A general modulation pattern is initially defined, the dc-link capacitor voltage balancing is analyzed in detail, and a proper balancing control is designed. Then, a set of decoupled optimization problems is formulated as a function of the available modulation degrees of freedom to minimize the predominant converter losses. Finally, a simple and practical specific modulation strategy is provided, resembling the optimum solutions. The good performance of the proposed three-level NPC DAB converter operated with the proposed modulation strategy and voltage balancing control is verified through simulation and experiments. The capacitor voltage balancing can be guaranteed for all operating conditions. In addition, it is concluded that the multilevel topology provides benefits compared with the conventional two-level DAB converter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Krismer, F., & Kolar, J. W. (2010) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2025284 · Cited by 470 · cited 1×
“As shown in [16] and [17], the transformer copper”
Background
Cited by
Isolated and Nonisolated DC-to-DC Converters for Medium-Voltage DC Networks: A Review
Alhurayyis, I., Elkhateb, A., & Morrow, J. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3028057 · Cited by 224
“They should provide high step-up ratio, electrical isolation, FTC, high efficiency and high power density, and implement the maximum-power-point tracking (MPPT) [4], [86], [91], [102]–[105].”
BackgroundInfluentialDual Phase-Shifted Modulation Strategy for the Three-Level Dual Active Bridge DC–DC Converter
Liu, P., Chen, C., Duan, S., & Zhu, W. (2017) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2017.2696488 · Cited by 163
A Novel Three-Level CLLC Resonant DC–DC Converter for Bidirectional EV Charger in DC Microgrids
Xuan, Y., Yang, X., Chen, W., Liu, T., & Hao, X. (2021) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2972446 · Cited by 156
“Three-level bidirectional dc–dc converters have been reported by some researchers [10]–[21].”
Background
Metadata
- Authors
- Filba-Martinez, A., Busquets-Monge, S., Nicolas-Apruzzese, J., & Bordonau, J.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2016-02
- Volume
- 63
- Issue
- 2
- Pages
- 678-690
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2249143921
- Cited by
- 168
- References
- 1
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.