A New Transformerless Buck–Boost Converter With Positive Output Voltage
The DOI matches its Crossref record; 22 of the 22 references it cites were found in a registry or an index.
Abstract
A new transformerless buck-boost converter with simple structure is proposed in this study. Compared with the traditional buck-boost converter, the proposed buck-boost converter's voltage gain is squared times of the former's and its output voltage polarity is positive. These advantages enable it to work in a wider range of positive output. The two power switches of the proposed buck-boost converter operate synchronously. In the continuous conduction mode (CCM), two inductors are magnetized and two capacitors are discharged during the switch-on period, while two inductors are demagnetized and two capacitors are charged during the switch-off period. The operating principles, the steady-state analyses, and the small-signal model for the proposed buck-boost converter operating in CCM are presented in detail. The power electronics simulator (PSIM) and the circuit experiments are provided to validate the effectiveness of the proposed buck-boost converter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A general unified approach to modelling switching-converter power stages
MIDDLEBROOK, R. D., & ĆUK, S. (1977) · International Journal of Electronics · doi:10.1080/00207217708900678 · Cited by 1,424
Review of Nonisolated High-Step-Up DC/DC Converters in Photovoltaic Grid-Connected Applications
Li, W., & He, X. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2049715 · Cited by 1,423
Axelrod, B., Berkovich, Y., & Ioinovici, A. (2008) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2008.916403 · Cited by 1,379 · cited 1×
“Additionally, some switched networks are added into the basic converters to obtain the high-voltage step-up or step-down gain, at the price of complicating construction and increasing cost [13]–[23].”
BackgroundTransformerless DC–DC Converters With High Step-Up Voltage Gain
Yang, L.-S., Liang, T.-J., & Chen, J.-F. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2022512 · Cited by 808
Voltage Multiplier Cells Applied to Non-Isolated DC–DC Converters
Prudente, M., Pfitscher, L. L., Emmendoerfer, G., Romaneli, E. F., & Gules, R. (2008) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2007.915762 · Cited by 750
Switching converters with wide DC conversion range
Maksimovic, D., & Cuk, S. (1991) · IEEE Transactions on Power Electronics · doi:10.1109/63.65013 · Cited by 637 · cited 1×
“The quadratic buck–boost converter, proposed by Maksimovic and Cuk in [24], has one common-ground power switch; meanwhile, it can achieve the voltage gain D2/(1−D)2.”
BackgroundA Family of Single-Switch PWM Converters With High Step-Up Conversion Ratio
Ismail, E. H., Al-Saffar, M. A., Sabzali, A. J., & Fardoun, A. A. (2008) · IEEE Transactions on Circuits and Systems I: Regular Papers · doi:10.1109/tcsi.2008.916427 · Cited by 359
A Switched-Capacitor-Based Active-Network Converter With High Voltage Gain
Tang, Y., Wang, T., & He, Y. (2014) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2272639 · Cited by 317
Pan, C., & Lai, C. (2009) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2009.2024100 · Cited by 217 · cited 1×
“A S is well known, switching-mode power supply is the core of modern power conversion technology, which is widely used in electric power, communication system, household appliance, industrial device, railway, aviation, and many other fields [1], [2].”
BackgroundQuadratic boost converter with low buffer capacitor stress
Ye, Y., & Eric Cheng, K. W. (2014) · IET Power Electronics · doi:10.1049/iet-pel.2013.0205 · Cited by 202 · cited 1×
“Quadratic converters can achieve the voltage gain of cascade converters with fewer switches; however, the efficiency of these converters are low [11], [12].”
Background
Cited by
Zhang, N., Zhang, G., See, K. W., & Zhang, B. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2717462 · Cited by 204
“Compared to the converter in [19], the proposed converter requires three more diodes.”
BackgroundMethodInfluentialNon-isolated buck–boost dc–dc converter with quadratic voltage gain ratio
Gorji, S. A., Mostaan, A., Tran My, H., & Ektesabi, M. (2019) · IET Power Electronics · doi:10.1049/iet-pel.2018.5703 · Cited by 109
Fardahar, S. M., & Sabahi, M. (2020) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2019.2932325 · Cited by 102
Metadata
- Authors
- Miao, S., Wang, F., & Ma, X.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2016-05
- Volume
- 63
- Issue
- 5
- Pages
- 2965-2975
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2326797614
- Cited by
- 227
- References
- 22
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.