Distributed Model Predictive Load Frequency Control of the Multi-Area Power System After Deregulation
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
This paper proposes a distributed model predictive control scheme for the load frequency control (LFC) problem of the deregulated multi-area interconnected power system with contracted and uncontracted load demands. The traditional LFC of the interconnected power system is modified to take into account the effect of bilateral contracts on the dynamics. The concept of the distribution company participation matrix and area participation matrix are introduced to simulate these bilateral contracts and reflected in the multi-area block diagram. The distributed model predictive controller is designed by posing the LFC problem as a tracking control problem in the presence of both external disturbances and constraints that represent generation rate constraint and load reference setpoint constraint, respectively. Analysis and simulation results for a deregulated three-area interconnected power system show possible improvements on closed-loop performance and computational burden, while respecting the physical hard constraints.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust Power System Frequency Control
Bevrani, H. (2009) · Springer eBooks · doi:10.1007/978-0-387-84878-5 · Cited by 1,164 · cited 1×
“The purpose of the load frequency control (LFC) is to keep the system frequency at the nominal value, maintain the interarea tie-line power flows at their prespecified values by manipulating the load reference setpoint considering load changes (disturbances) and system nonlinearities (constraints) [1].”
BackgroundDistributed MPC Strategies With Application to Power System Automatic Generation Control
Venkat, A. N., Hiskens, I. A., Rawlings, J. B., & Wright, S. J. (2008) · IEEE Transactions on Control Systems Technology · doi:10.1109/tcst.2008.919414 · Cited by 811
Distributed receding horizon control for multi-vehicle formation stabilization
Dunbar, W. B., & Murray, R. M. (2006) · Automatica · doi:10.1016/j.automatica.2005.12.008 · Cited by 757 · cited 1×
“, at each time step, the newly calculated optimal trajectories of each system must not deviate too much from the ones calculated at the previous time step [24] or from the ones that the neighboring systems assumed [25].”
BackgroundSimulation and optimization in an AGC system after deregulation
Donde, V., Pai, M. A., & Hiskens, I. A. (2001) · IEEE Transactions on Power Systems · doi:10.1109/59.932285 · Cited by 516
Decentralized receding horizon control for large scale dynamically decoupled systems
Keviczky, T., Borrelli, F., & Balas, G. J. (2006) · Automatica · doi:10.1016/j.automatica.2006.07.008 · Cited by 424 · cited 1×
“, at each time step, the newly calculated optimal trajectories of each system must not deviate too much from the ones calculated at the previous time step [24] or from the ones that the neighboring systems assumed [25].”
BackgroundRobust distributed model predictive control
Richards, A., & How, J. P. (2007) · International Journal of Control · doi:10.1080/00207170701491070 · Cited by 344
Model Predictive Load-Frequency Control
Ersdal, A. M., Imsland, L., & Uhlen, K. (2015) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2015.2412614 · Cited by 285
A robust decentralized load frequency controller for interconnected power systems
Dong, L., Zhang, Y., & Gao, Z. (2012) · ISA Transactions · doi:10.1016/j.isatra.2012.02.004 · Cited by 225 · cited 2×
“, see [8] and [9]), sliding mode control (e.”
BackgroundKhooban, M. H., & Niknam, T. (2015) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.03.017 · Cited by 191
Load frequency control of power system under deregulated environment using optimal firefly algorithm
Chandra Sekhar, G. T., Sahu, R. K., Baliarsingh, A. K., & Panda, S. (2016) · International Journal of Electrical Power & Energy Systems · doi:10.1016/j.ijepes.2015.07.025 · Cited by 186 · cited 1×
“tem are required to restore frequency and tie-line deviations, and also coordinate power contracts between various business entities [2].”
Background
Cited by
Alhelou, H. H., Hamedani-Golshan, M.-E., Zamani, R., Heydarian-Forushani, E., & Siano, P. (2018) · Energies · doi:10.3390/en11102497 · Cited by 349
“[170] Traditional 2 Thermal No 2-DOF PID DE [45] Deregulated 2 Hydro–Thermal Yes DFIGs FLC Fuzzy [296] Traditional 2 Hydro–Thermal–Gas Yes TCSC I IPSO [103] Deregulated 2 Hydro–Thermal–Gas Yes OOFC [297] Traditional 2 Hydro–Thermal–Wind–Diesel Yes PIDD TLBO [298] Deregulated 2 Thermal–Gas Yes I,PI,ID,PID DE [101] Dere…”
Latif, A., Hussain, S. M. S., Das, D. C., & Ustun, T. S. (2020) · Applied Energy · doi:10.1016/j.apenergy.2020.114858 · Cited by 183
Kumar, R., & Sharma, V. K. (2021) · International Journal of Numerical Modelling: Electronic Networks, Devices and Fields · doi:10.1002/jnm.2802 · Cited by 14
“The conversion of the non-linearized model into a linearized model is done by using Equation (9) and (10).”
Method
Metadata
- Authors
- Ma, M., Zhang, C., Liu, X., & Chen, H.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-06
- Volume
- 64
- Issue
- 6
- Pages
- 5129-5139
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2524758238
- Cited by
- 168
- References
- 19
- FWCI
- 7.32
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.