The DOI matches its Crossref record.
Compliance-Based Robotic Peg-in-Hole Assembly Strategy Without Force Feedback
Abstract
The peg-in-hole assembly is a representative robotic task that involves physical contact with the external environment. In this paper, in contrast to past research in the area, which has involved the utilization of such expensive devices as force/torque sensors or remote compliance mechanisms, an inexpensive method is proposed for peg-in-hole assembly without force feedback or passive compliance mechanisms. The method consists of an analysis of the state of contact between the peg and the hole as well as a strategy to overcome the inevitable positional uncertainty of the hole incurred in the recognition process. A control scheme was developed to yield compliant behavior from the robot with physical contact under the condition of hybrid position/force control. The effectiveness of the proposed method was experimentally verified using a robot manipulator with 8-degrees of freedom and a peg-in-hole apparatus with a small clearance (0.1 mm).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Proactive human–robot collaboration: Mutual-cognitive, predictable, and self-organising perspectives
Li, S., Zheng, P., Liu, S., Wang, Z., Wang, X. V., Zheng, L., & Wang, L. (2023) · Robotics and Computer-Integrated Manufacturing · doi:10.1016/j.rcim.2022.102510 · Cited by 265
Roveda, L., Magni, M., Cantoni, M., Piga, D., & Bucca, G. (2021) · Robotics and Autonomous Systems · doi:10.1016/j.robot.2020.103711 · Cited by 80
Metadata
- Authors
- Park, H., Park, J., Lee, D.-H., Park, J.-H., Baeg, M.-H., & Bae, J.-H.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-08
- Volume
- 64
- Issue
- 8
- Pages
- 6299-6309
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2612089457
- Cited by
- 200
- References
- 0
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.