The DOI matches its Crossref record.
Improved Sliding Mode Design for Load Frequency Control of Power System Integrated an Adaptive Learning Strategy
Open accessAbstract
Randomness from the power load demand and renewable generations causes frequency oscillations among interconnected power systems. Due to the requirement of synchronism of the whole grid, load frequency control (LFC) has become one of the essential challenges for power system stability and security. In this paper, by modeling the disturbances and parameter uncertainties into the LFC model, we propose an adaptive supplementary control scheme for the power system frequency regulation. An improved sliding mode control (SMC) is employed as the basic controller, where a new sliding mode variable is specifically proposed for the LFC problem. The adaptive dynamic programming strategy is used to provide the supplementary control signal, which is beneficial to the frequency regulation by adapting to the real-time disturbances and uncertainties. The stability analysis is also provided to guarantee the reliability of the proposed control strategy. For comparison, a particle swarm optimization-based SMC scheme is developed as the optimal parameter controller for the frequency regulation problem. Simulation studies are performed on single-area and multiarea benchmark systems, and comparative results illustrate the favorable performance of the proposed adaptive approach for the frequency regulation under load disturbances and parameter uncertainties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Yan, Z., & Xu, Y. (2020) · IEEE Transactions on Power Systems · doi:10.1109/tpwrs.2020.2999890 · Cited by 398
Adaptive Critic Nonlinear Robust Control: A Survey
Wang, D., He, H., & Liu, D. (2017) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2017.2712188 · Cited by 374
Self-citationMa, L., Huo, X., Zhao, X., Niu, B., & Zong, G. (2019) · Neurocomputing · doi:10.1016/j.neucom.2019.04.049 · Cited by 111
A review of control techniques for inverter-based distributed energy resources applications
Hasheminasab, S., Alzayed, M., & Chaoui, H. (2024) · Energies · doi:10.3390/en17122940 · Cited by 56
Metadata
- Authors
- Mu, C., Tang, Y., & He, H.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-08
- Volume
- 64
- Issue
- 8
- Pages
- 6742-6751
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2606262161
- Cited by
- 240
- References
- 0
- FWCI
- 9.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Improved Sliding Mode Design for Load Frequency Control of Power System Integrated an Adaptive Learning Strategy. https://app.cochat.ai/papers/10.1109/tie.2017.2694396
- The paper
- Mu, C., Tang, Y., & He, H. (2017). Improved Sliding Mode Design for Load Frequency Control of Power System Integrated an Adaptive Learning Strategy. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2017.2694396
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.