A Multilevel Transformerless Inverter Employing Ground Connection Between PV Negative Terminal and Grid Neutral Point
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
For the safe operation of transformerless grid connected photovoltaic (PV) inverters, the issue of common mode (CM) leakage current needs to be addressed carefully. In this paper, a novel multilevel transformerless inverter topology is proposed, which completely eliminates CM leakage current by connecting grid neutral point directly to the PV negative terminal, thereby bypassing the PV stray capacitance. It provides a low-cost solution consisting of only four power switches, two capacitors, and a single filter inductor. As compared to half-bridge topologies, with this inverter a minimum of 27% and maximum of 100% more output voltage is obtained for the same dc-link voltage. The proposed inverter is analyzed in detail and its switching pattern to generate multilevel output while maintaining the capacitor voltage is discussed. Simulations and experiments results confirm the feasibility and good performance of the proposed inverter.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Power Electronics at the Grid Edge : The key to unlocking value from the smart grid
Divan, D., Moghe, R., & Prasai, A. (2014) · IEEE Power Electronics Magazine · doi:10.1109/mpel.2014.2360811 · Cited by 58
Cited by
Salem, A., Van Khang, H., Robbersmyr, K. G., Norambuena, M., & Rodriguez, J. (2021) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2020.3011908 · Cited by 285
A Review on Reduced Switch Count Multilevel Inverter Topologies
Omer, P., Kumar, J., & Surjan, B. S. (2020) · IEEE Access · doi:10.1109/access.2020.2969551 · Cited by 226
Metadata
- Authors
- Kadam, A., & Shukla, A.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2017-11
- Volume
- 64
- Issue
- 11
- Pages
- 8897-8907
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2608379776
- Cited by
- 181
- References
- 1
- FWCI
- 6.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.