A Piezoelectric-Driven Linear Actuator by Means of Coupling Motion
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
A piezoelectric-driven actuator based on coupling motion has been proposed and tested to achieve a large linear working stroke with high resolution. “Z-shaped” flexure hinges are exploited for the symmetric flexure hinge mechanism to reduce the structural stress. Coupling motion is obtained by placing this symmetric flexure hinge mechanism with an angle of θ = 20° to the slider. Experimental results indicate that linear motion with a large working stroke is effectively obtained by this coupling motion; the maximum motion speed is Vs= 6057 μm/s and the maximum output force is Fg= 350 g. Additionally, the influences of input frequency f and input voltage Ueare investigated, and the system kinetic model is established to better analyze the performance of this designed piezoelectric-driven linear actuator.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Dagdeviren, C., Shi, Y., Joe, P., Ghaffari, R., Balooch, G., Usgaonkar, K., Gur, O., Tran, P. L., Crosby, J. R., Meyer, M., et al. (2015) · Nature Materials · doi:10.1038/nmat4289 · Cited by 513 · cited 1×
“In recent years, several flexible micropiezoelectric actuators have been developed for clinical and microenergy harvesting science to obtain microspatial resolution; unfortunately, the working stroke and output force are still rather small [18]–[21].”
Background
Metadata
- Authors
- Li, J., Huang, H., & Zhao, H.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2018-03
- Volume
- 65
- Issue
- 3
- Pages
- 2458-2466
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2745360405
- Cited by
- 160
- References
- 1
- FWCI
- 8.61
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.