An Effective Sandwiched Wireless Power Transfer System for Charging Implantable Cardiac Pacemaker
The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
This paper presents a new effective sandwiched wireless power transfer (WPT) system, which is adopted to recharge the battery of a micro medical robotics for a cardiac pacemaker. The key of the design is to use the distinct sandwiched topology in both the transmitter and receiver coils, whose operating frequency of 160 kHz is significantly lower than the reported WPT system up to megahertz. Furthermore, the implantable receiver adopts the bilateral coil design, which can harness more power within a limited size. Meanwhile, with the sandwiched transmitting coils, the proposed design achieves the high feasibility and flexibility of the controllable distance for different kinds of micro medical robotics in patients. As a result, the proposed system can provide the power as high as 5 W and the transmission efficiency up to 88%. Finally, the corresponding theoretical analysis, simulation, and experimentation are carried out to prove the validity of the proposed sandwiched medical WPT system for the implantable device in the patient body.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Sample, A. P., Meyer, D. A., & Smith, J. R. (2011) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2010.2046002 · Cited by 1,808
Covic, G. A., & Boys, J. T. (2013) · Proceedings of the IEEE · doi:10.1109/jproc.2013.2244536 · Cited by 1,223 · cited 1×
“[1]–[3].”
Modern Advances in Wireless Power Transfer Systems for Roadway Powered Electric Vehicles
Mi, C. C., Buja, G., Choi, S. Y., & Rim, C. T. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2574993 · Cited by 841
Robust wireless power transfer using a nonlinear parity–time-symmetric circuit
Assawaworrarit, S., Yu, X., & Fan, S. (2017) · Nature · doi:10.1038/nature22404 · Cited by 812
Zhou, S., & Chris Mi, C. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2512236 · Cited by 251
Wireless Power Transfer Charging System for AIMDs and Pacemakers
Campi, T., Cruciani, S., Palandrani, F., De Santis, V., Hirata, A., & Feliziani, M. (2016) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2015.2511011 · Cited by 243 · cited 2×
“According to the European specific absorption rating (SAR), this proposed system is below the SAR limit of 2 W/kg, which represents 1 A transmitter at the operating frequency of 8 MHz [34].”
BackgroundXiao, C., Cheng, D., & Wei, K. (2018) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2017.2735441 · Cited by 240 · cited 6×
“2) The distance between transmission coils and receive coil is various for different people, but usually it can be set as 200 mm. 3) Actually for the data transmission or ultralow power transmission (μW) of medical implanted devices, the radio frequency should be close to 400 MHz [32].”
MethodInfluentialCompensation of Cross Coupling in Multiple-Receiver Wireless Power Transfer Systems
Fu, M., Zhang, T., Zhu, X. A., Luk, P. C. K., & Ma, C. (2016) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2016.2516906 · Cited by 211 · cited 1×
“maximum value, namely, reducing or even eliminating the reactive power Qtrans in the transmission channel, which can be expressed as follows [5]–[7]:”
BackgroundAn Overview of Resonant Circuits for Wireless Power Transfer
Jiang, C., Chau, K. T., Liu, C., & Lee, C. H. T. (2017) · Energies · doi:10.3390/en10070894 · Cited by 186 · cited 4×
“Then, the reflected resistance and reactance be derived as follows [4]:”
BackgroundMethodSelf-citationA Triple-Loop Inductive Power Transmission System for Biomedical Applications
Lee, B., Kiani, M., & Ghovanloo, M. (2015) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2014.2376965 · Cited by 159 · cited 1×
“For the one side, a higher resonant frequency achieves a better capability of power transmission under the same distance for charging micro medical robotics [27], [28].”
Background
Cited by
Near-field wireless power transfer used in biomedical implants: a comprehensive review
Mahmood, A. I., Gharghan, S. K., Eldosoky, M. A., & Soliman, A. M. (2022) · IET Power Electronics · doi:10.1049/pel2.12351 · Cited by 59
Metadata
- Authors
- Liu, C., Jiang, C., Song, J., & Chau, K. T.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2019-05
- Volume
- 66
- Issue
- 5
- Pages
- 4108-4117
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2806959900
- Cited by
- 176
- References
- 23
- FWCI
- 6.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.