The DOI matches its Crossref record; 17 of the 21 references it cites were found in a registry or an index.
An Enhanced Closed-Loop Control Strategy With Capacitor Voltage Elevation for the DC–DC Modular Multilevel Converter
Abstract
The dc-dc modular multilevel converter (MMC), derived from the ac-dc MMC, is an attractive converter topology for interconnection of medium-/high-voltage dc grids. The dc-dc MMC generates an ac voltage component in each arm to drive an ac circulating current for maintaining the energy balance of its submodule capacitors. The power transfer capability of the dc-dc MMC and the amplitude of the ac circulating current are closely coupled with the available arm ac voltage headroom. As the voltage conversion ratio of the dc-dc MMC deviates from 0.5, the power transfer capability of the converter diminishes. This paper proposes an enhanced closed-loop control strategy, which increases the power transfer capability and at the same time reduces the ac circulating current of the dc-dc MMC. Performance and effectiveness of the proposed control strategy are demonstrated by simulation studies in the MATLAB/Simulink as well as experiments conducted on a laboratory prototype.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Engel, S. P., Stieneker, M., Soltau, N., Rabiee, S., Stagge, H., & De Doncker, R. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2014.2310656 · Cited by 443 · cited 1×
“In practice, coupled inductors can be used as they filter out the ac current components, while ensuring cancellation of the dc flux in the inductor core [17].”
MethodThe Multilevel Modular DC Converter
Ferreira, J. A. (2013) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2012.2237413 · Cited by 371 · cited 1×
“Operation and dynamic modeling of the dc–dc MMC are studied in [6]–[11].”
BackgroundA Modular Multilevel DC/DC Converter With Fault Blocking Capability for HVDC Interconnects
Kish, G. J., Ranjram, M., & Lehn, P. W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2013.2295967 · Cited by 263
Feasibility of DC transmission networks
Jovcic, D., van Hertem, D., Linden, K., Taisne, J.-P., & Grieshaber, W. (2011) · 2011 2nd IEEE PES International Conference and Exhibition on Innovative Smart Grid Technologies · doi:10.1109/isgteurope.2011.6162829 · Cited by 190
Technical Guidelines and Prestandardization Work for First HVDC Grids
Akhmatov, V., Callavik, M., Franck, C. M., Rye, S. E., Ahndorf, T., Bucher, M. K., Muller, H., Schettler, F., & Wiget, R. (2014) · IEEE Transactions on Power Delivery · doi:10.1109/tpwrd.2013.2273978 · Cited by 176
A Novel Medium-Voltage Modular Multilevel DC–DC Converter
Du, S., Wu, B., Tian, K., Xu, D. D., & Zargari, N. R. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2542130 · Cited by 104 · cited 1×
“Several modifications and alternative filtering options have been proposed to reduce the volume and cost of the converter [12]–[14].”
BackgroundYang, H., & Saeedifard, M. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2016.2613059 · Cited by 103 · cited 5×
“A closed-loop capacitor voltage balancing strategy is proposed in [16] to regulate the converter power flow, maintain the energy balance of the SM capacitors, and minimize the ac circulating current.”
BackgroundMethodSelf-citationThe polyphase cascaded-cell DC/DC converter
Norrga, S., Ängquist, L., & Antonopoulos, A. (2013) · IEEE Energy Conversion Congress and Exposition (ECCE) · doi:10.1109/ecce.2013.6647243 · Cited by 85 · cited 2×
“1) Constraint I: Based on conventional control strategies [6], [7], [16], the SM capacitor voltages are maintained at VC,base = Vdc2 N , and consequently, v (x ∈ p, n) ≤ Vdc2 must be satisfied.”
BackgroundDC–DC Autotransformer With Bidirectional DC Fault Isolating Capability
Lin, W. (2015) · IEEE Transactions on Power Electronics · doi:10.1109/tpel.2015.2491781 · Cited by 74 · cited 1×
“, for interconnection of dc grids [1]–[5].”
Wu, L., Qin, J., Saeedifard, M., Wasynczuk, O., & Shenai, K. (2015) · IEEE Transactions on Electron Devices · doi:10.1109/ted.2014.2375875 · Cited by 73
Self-citation
Research works printed but not linked: 1
- barker, 0, Requirements of DC-DC converters to facilitate large DC grids, Proc CIGRE Symp, 1
Cited by
Modular Multilevel Converters: Recent Achievements and Challenges
Perez, M. A., Ceballos, S., Konstantinou, G., Pou, J., & Aguilera, R. P. (2021) · IEEE Open Journal of the Industrial Electronics Society · doi:10.1109/ojies.2021.3060791 · Cited by 327
“generate a controllable dc output voltage, while a circulating current is forced to circulate among the arms in order to balance the capacitor voltages [147].”
BackgroundIsolated and Nonisolated DC-to-DC Converters for Medium-Voltage DC Networks: A Review
Alhurayyis, I., Elkhateb, A., & Morrow, J. (2021) · IEEE Journal of Emerging and Selected Topics in Power Electronics · doi:10.1109/jestpe.2020.3028057 · Cited by 224
“Furthermore, it is possible to combine both types of SMs in the configuration of the converter to take their advantages [80].”
BackgroundMethodInfluentialBeyond the MMC: Extended Modular Multilevel Converter Topologies and Applications
Sun, P., Tian, Y., Pou, J., & Konstantinou, G. S. (2022) · IEEE Open Journal of Power Electronics · doi:10.1109/ojpel.2022.3175714 · Cited by 108
Modular High-Power DC–DC Converter for MVDC Renewable Energy Collection Systems
Li, B., Liu, J., Wang, Z., Zhang, S., & Xu, D. (2020) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2020.2994878 · Cited by 55
“ering the MMC FTF [18], MMC dc AT [27], single-stage MMC dcndash;dc converter [26], and hybrid cascaded dcndash;dc converter [28].”
MethodDevelopment of PID based control strategy in maximum exergy efficiency of a geothermal power plant
Çetin, G., Özkaraca, O., & Keçebaş, A. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110623 · Cited by 44
Metadata
- Authors
- Yang, H., Saeedifard, M., & Yazdani, A.
- Affiliations
- Georgia Institute of Technology (US)
- Toronto Metropolitan University (CA)
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2019-03
- Volume
- 66
- Issue
- 3
- Pages
- 2366-2375
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W2810651452
- Cited by
- 52
- References
- 21
- Citations by year
- 2026: 5 · 2025: 4 · 2024: 2 · 2023: 5 · 2022: 7 · 2021: 12 · 2020: 11 · 2019: 3
- FWCI
- 2.77
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- IEEE Transactions on Industrial Electronics (publishedVersion)
- Funders
- Clusters for Grand Challenges supplement (NSF I/UCRC Award No. 1134867)
- Topics
- Physical Sciences › Engineering › Electrical and Electronic Engineering › HVDC Systems and Fault Protection
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Multilevel Inverters and Converters
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced DC-DC Converters
- Keywords
- feedback control, capacitor voltage balancing, power transfer capability, voltage conversion ratio, DC grid interconnection
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Enhanced Closed-Loop Control Strategy With Capacitor Voltage Elevation for the DC–DC Modular Multilevel Converter. https://app.cochat.ai/papers/10.1109/tie.2018.2850035
- The paper
- Yang, H., Saeedifard, M., & Yazdani, A. (2019). An Enhanced Closed-Loop Control Strategy With Capacitor Voltage Elevation for the DC–DC Modular Multilevel Converter. IEEE Transactions on Industrial Electronics. https://doi.org/10.1109/tie.2018.2850035
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.