A Just-In-Time-Learning-Aided Canonical Correlation Analysis Method for Multimode Process Monitoring and Fault Detection
The DOI matches its Crossref record; 41 of the 41 references it cites were found in a registry or an index.
Abstract
In this article, a just-in-time-learning (JITL)-aided canonical correlation analysis (CCA) is proposed for the monitoring and fault detection of multimode processes. A canonical correlation analysis (CCA)-based fault detection method has been applied to single-operating-mode processes. However, CCA has limitations in handling processes with multiple operating points. These limitations are illustrated by a numerical example. To reduce the time for searching relevant data, K-means is integrated into the JITL to build the local CCA model. Furthermore, the proposed method is compared with commonly used kernel-based methods in terms of computational complexity and interpretability of the results. Finally, the validity and efficacy of the proposed method are shown using an industrial benchmark process. Results show that the proposed method has better performance than conventional methods in terms of fault detection rate while still tracking changes in the system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135
Self-citationIsermann, R. (2006) · Springer eBooks · doi:10.1007/3-540-30368-5 · Cited by 2,217
Statistical process monitoring: basics and beyond
Joe Qin, S. (2003) · Journal of Chemometrics · doi:10.1002/cem.800 · Cited by 1,582 · cited 2×
“The interest of PMFD has also shifted from model-based methods [5], [6] to data-driven methods [7]–[9] because of difficulties in modeling complex processes and the increasing availability of sensors and high-performance computational devices.”
MethodYin, S., Ding, S. X., Haghani, A., Hao, H., & Zhang, P. (2012) · Journal of Process Control · doi:10.1016/j.jprocont.2012.06.009 · Cited by 1,294 · cited 2×
“The FAR and the FDR can be estimated as follows [10]:”
MethodSelf-citationStatistical process control of multivariate processes
MacGregor, J. F., & Kourti, T. (1995) · Control Engineering Practice · doi:10.1016/0967-0661(95)00014-l · Cited by 1,270 · cited 1×
“S INCE the pioneering work of Dr. W. A. Shewhart in the early 1920s [1], [2] and the work of Dr. J. F. MacGregor in the early 1990s [3], [4], PMFD has become a well-accepted practice in modern processes.”
BackgroundNonlinear process monitoring using kernel principal component analysis
Lee, J.-M., Yoo, C., Choi, S. W., Vanrolleghem, P. A., & Lee, I.-B. (2004) · Chemical Engineering Science · doi:10.1016/j.ces.2003.09.012 · Cited by 1,086 · cited 4×
“Furthermore, kernel principal component analysis (KPCA) [43] was applied to this case with T 2 and SPE statistics as well (see Fig.”
MethodInfluentialMultivariate statistical monitoring of process operating performance
Kresta, J. V., Macgregor, J. F., & Marlin, T. E. (1991) · The Canadian Journal of Chemical Engineering · doi:10.1002/cjce.5450690105 · Cited by 989 · cited 1×
“MacGregor in the early 1990s [3], [4], PMFD has become a well-accepted practice in modern processes.”
BackgroundReview of Recent Research on Data-Based Process Monitoring
Ge, Z., Song, Z., & Gao, F. (2013) · Industrial & Engineering Chemistry Research · doi:10.1021/ie302069q · Cited by 967 · cited 2×
“Based on the work in [26] and [27], four types of methods can be found: adaptive/recursive methods, multimodel methods, mixture modeling methods, and local-learning methods.”
BackgroundMethodRecursive PCA for adaptive process monitoring
Li, W., Yue, H. H., Valle-Cervantes, S., & Qin, S. J. (2000) · Journal of Process Control · doi:10.1016/s0959-1524(00)00022-6 · Cited by 848 · cited 2×
“Based on their discussions, these methods can be classified into four types: adaptive/recursive methods [28], [29], multimodel approaches [25], [30], [31], mixture modeling methods [27], [32]–[34], and local-learning methods [35]–[37].”
BackgroundMethodGao, Z., Cecati, C., & Ding, S. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2419013 · Cited by 776 · cited 1×
“The interest of PMFD has also shifted from model-based methods [5], [6] to data-driven methods [7]–[9] because of difficulties in modeling complex processes and the increasing availability of sensors and high-performance computational devices.”
MethodSelf-citation
Cited by
Quo vadis artificial intelligence?
Jiang, Y., Li, X., Luo, H., Yin, S., & Kaynak, O. (2022) · Discover Artificial Intelligence · doi:10.1007/s44163-022-00022-8 · Cited by 544
Chen, H., Jiang, B., Ding, S. X., & Huang, B. (2022) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2020.3029946 · Cited by 521
Self-citationChen, L., Wang, K., Li, M., Wu, M., Pedrycz, W., & Hirota, K. (2023) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2022.3150097 · Cited by 113
Metadata
- Authors
- Chen, Z., Liu, C., Ding, S. X., Peng, T., Yang, C., Gui, W., & Shardt, Y. A. W.
- Venue
- IEEE Transactions on Industrial Electronics
- Published
- 2021-06
- Volume
- 68
- Issue
- 6
- Pages
- 5259-5270
- ISSN
- 0278-0046 (ISSN-L)
- 1557-9948
- OpenAlex
- W3023056142
- Cited by
- 159
- References
- 41
- FWCI
- 10.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.