The DOI matches its Crossref record.
Reconfigurable Monitoring System for Time-Frequency Analysis on Industrial Equipment Through STFT and DWT
Abstract
Nowadays industry pays much attention to prevent failures that may interrupt production with severe consequences in cost, product quality, and safety. The most-analyzed parameters for monitoring dynamic characteristics and ensuring correct functioning of systems are electric current, voltage, and vibrations. System-on-chip (SoC) design is an approach to increase performance and overcome costs during equipment monitoring. This work presents the design and implementation of a low-cost SoC design that utilizes reconfigurable hardware and a customized embedded processor for time-frequency analysis on industrial equipment through short-time Fourier transform and discrete wavelet transform. Three study cases (electric current supply to an induction motor during startup transient, voltage supply to an induction motor through a variable speed drive, and vibration signals from industrial-robot links) show the suitability of the proposed monitoring system for time-frequency analysis of different signals in distinct industrial applications, and early diagnosis and prognosis of abnormalities in monitored systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Gao, Z., Cecati, C., & Ding, S. X. (2015) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2417501 · Cited by 3,135
“In [162], the STFT and the discrete WT were integrated to do early diagnosis and prognosis of the abnormalities in the monitored industrial systems.”
MethodTian, J., Morillo, C., Azarian, M. H., & Pecht, M. (2016) · IEEE Transactions on Industrial Electronics · doi:10.1109/tie.2015.2509913 · Cited by 488
A Review of Fault Detection and Diagnosis for the Traction System in High-Speed Trains
Chen, H., & Jiang, B. (2020) · IEEE Transactions on Intelligent Transportation Systems · doi:10.1109/tits.2019.2897583 · Cited by 413
Convolutional Discriminative Feature Learning for Induction Motor Fault Diagnosis
Sun, W., Zhao, R., Yan, R., Shao, S., & Chen, X. (2017) · IEEE Transactions on Industrial Informatics · doi:10.1109/tii.2017.2672988 · Cited by 295
Faults and Diagnosis Methods of Permanent Magnet Synchronous Motors: A Review
Chen, Y., Liang, S., Li, W., Liang, H., & Wang, C. (2019) · Applied Sciences · doi:10.3390/app9102116 · Cited by 194
Metadata
- Authors
- Cabal-Yepez, E., Garcia-Ramirez, A. G., Romero-Troncoso, R. J., Garcia-Perez, A., & Osornio-Rios, R. A.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2013-05
- Volume
- 9
- Issue
- 2
- Pages
- 760-771
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W2061698056
- Cited by
- 177
- References
- 0
- FWCI
- 10.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reconfigurable Monitoring System for Time-Frequency Analysis on Industrial Equipment Through STFT and DWT. https://app.cochat.ai/papers/10.1109/tii.2012.2221131
- The paper
- Cabal-Yepez, E., Garcia-Ramirez, A. G., Romero-Troncoso, R. J., Garcia-Perez, A., & Osornio-Rios, R. A. (2013). Reconfigurable Monitoring System for Time-Frequency Analysis on Industrial Equipment Through STFT and DWT. IEEE Transactions on Industrial Informatics. https://doi.org/10.1109/tii.2012.2221131
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.