EDL-COVID: Ensemble Deep Learning for COVID-19 Case Detection From Chest X-Ray Images
Open accessThe DOI matches its Crossref record; 34 of the 34 references it cites were found in a registry or an index.
Abstract
Effective screening of COVID-19 cases has been becoming extremely important to mitigate and stop the quick spread of the disease during the current period of COVID-19 pandemic worldwide. In this article, we consider radiology examination of using chest X-ray images, which is among the effective screening approaches for COVID-19 case detection. Given deep learning is an effective tool and framework for image analysis, there have been lots of studies for COVID-19 case detection by training deep learning models with X-ray images. Although some of them report good prediction results, their proposed deep learning models might suffer from overfitting, high variance, and generalization errors caused by noise and a limited number of datasets. Considering ensemble learning can overcome the shortcomings of deep learning by making predictions with multiple models instead of a single model, we proposeEDL-COVID, an ensemble deep learning model employing deep learning and ensemble learning. The EDL-COVID model is generated by combining multiple snapshot models of COVID-Net, which has pioneered in an open-sourced COVID-19 case detection method with deep neural network processed chest X-ray images, by employing a proposed weighted averaging ensembling method that is aware of different sensitivities of deep learning models on different classes types. Experimental results show that EDL-COVID offers promising results for COVID-19 case detection with an accuracy of 95%, better than COVID-Net of 93.3%.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Clinical features of patients infected with 2019 novel coronavirus in Wuhan, China
Huang, C., Wang, Y., Li, X., Ren, L., Zhao, J., Hu, Y., Zhang, L., Fan, G., Xu, J., Gu, X., et al. (2020) · The Lancet · doi:10.1016/s0140-6736(20)30183-5 · Cited by 48,884 · cited 1×
“China at the earlier stage of the global outbreak [15], [16], [38].”
BackgroundClinical characteristics of coronavirus disease 2019 in China
Guan, W.-J., Ni, Z.-Y., Hu, Y., Liang, W.-H., Ou, C.-Q., He, J.-X., Liu, L., Shan, H., Lei, C.-L., Hui, D. S. C., et al. (2020) · New England Journal of Medicine · doi:10.1056/nejmoa2002032 · Cited by 30,246
SGDR: Stochastic Gradient Descent with Warm Restarts
Loshchilov, I., & Hutter, F. (2016) · arXiv · doi:10.48550/arxiv.1608.03983 · Cited by 5,309 · cited 3×
“By using COVIDNet network architecture as well as its datasets of COVIDx [2], we first train multiple snapshot deep learning models with a cosine annealing learning rate schedule, for which the learning rate fluctuates significantly in that it starts high and drops to a minimum value close to zero rapidly before going…”
BackgroundMethodInfluentialUnderstanding of a convolutional neural network
Albawi, S., Mohammed, T. A., & Al-Zawi, S. (2017) · 2017 International Conference on Engineering and Technology (ICET) · doi:10.1109/icengtechnol.2017.8308186 · Cited by 3,986 · cited 1×
“In comparison, CNN is the most popular one, which is good for applications such as image detection/recognition, image classification, and medical image analysis [5].”
BackgroundWang, L., Lin, Z. Q., & Wong, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-76550-z · Cited by 3,113 · cited 8×
“[36] made a tailored and first open-sourced deep neural network called COVID-Net for COVID-19 case detection with CXR images.”
BackgroundMethodInfluentialWynants, L., Van Calster, B., Bonten, M. M., Collins, G. S., Debray, T. P., De Vos, M., Haller, M. C., Heinze, G., Moons, K. G., Riley, R. D., et al. (2020) · doi:10.1101/2020.03.24.20041020 · Cited by 3,070
Automated detection of COVID-19 cases using deep neural networks with X-ray images
Ozturk, T., Talo, M., Yildirim, E. A., Baloglu, U. B., Yildirim, O., & Rajendra Acharya, U. (2020) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2020.103792 · Cited by 2,594 · cited 1×
“[27] trained a deep learning scheme named DarkCovidNet, which detects COVID19 cases based on a number of only 125 CXR images.”
BackgroundNarin, A., Kaya, C., & Pamuk, Z. (2021) · Pattern Analysis and Applications · doi:10.1007/s10044-021-00984-y · Cited by 2,054 · cited 2×
“[26] made a comparison of different CNN models (e.”
BackgroundResultCan AI help in screening viral and COVID-19 pneumonia?
Chowdhury, M. E. H., Rahman, T., Khandakar, A., Mazhar, R., Kadir, M. A., Mahbub, Z. B., Islam, K. R., Khan, M. S., Iqbal, A., Emadi, N. A., et al. (2020) · IEEE Access · doi:10.1109/access.2020.3010287 · Cited by 1,913 · cited 1×
“[11] made a model training comparison of different deep learning networks including AlexNet, ResNet18, DenseNet201, and SqueezeNet to classify two classes (i.”
BackgroundLakhani, P., & Sundaram, B. (2017) · Radiology · doi:10.1148/radiol.2017162326 · Cited by 1,775 · cited 1×
“Essentially, COVID-19 cases detection with CXR images is a classification problem in machine learning domain, for which Convolutional neural network (CNNs) enabled data-driven deep learning methods have demonstrated promising performance [21].”
Background
Cited by
COVID-CXNet: Detecting COVID-19 in frontal chest X-ray images using deep learning
Haghanifar, A., Majdabadi, M. M., Choi, Y., Deivalakshmi, S., & Ko, S. (2022) · Multimedia Tools and Applications · doi:10.1007/s11042-022-12156-z · Cited by 183
Metadata
- Authors
- Tang, S., Wang, C., Nie, J., Kumar, N., Zhang, Y., Xiong, Z., & Barnawi, A.
- Venue
- IEEE Transactions on Industrial Informatics
- Published
- 2021-09
- Volume
- 17
- Issue
- 9
- Pages
- 6539-6549
- ISSN
- 1551-3203 (ISSN-L)
- 1941-0050
- OpenAlex
- W3128189270
- Cited by
- 172
- References
- 34
- FWCI
- 17.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.