Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 256

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Nonintrusive Load Monitoring and Diagnostics in Power Systems

Shaw, S.R., Leeb, S.B., Norford, L.K., Cox, R.W.·2008·IEEE Transactions on Instrumentation and Measurement

Abstract

This paper describes a transient event classification scheme, system identification techniques, and implementation for use in nonintrusive load monitoring. Together, these techniques form a system that can determine the operating schedule and find parameters of physical models of loads that are connected to an AC or DC power distribution system. The monitoring system requires only off-the-shelf hardware and recognizes individual transients by disaggregating the signal from a minimal number of sensors that are installed at a central location in the distribution system. Implementation details and field tests for AC and DC systems are presented.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1109/tim.2008.917179

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 256

Metadata

Authors
Shaw, S. R., Leeb, S. B., Norford, L. K., & Cox, R. W.
Venue
IEEE Transactions on Instrumentation and Measurement
Published
2008-07
Volume
57
Issue
7
Pages
1445-1454
ISSN
  • 0018-9456 (ISSN-L)
  • 1557-9662
OpenAlex
W2117995571
Cited by
256
References
4
FWCI
15.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Nonintrusive Load Monitoring and Diagnostics in Power Systems. https://app.cochat.ai/papers/10.1109/tim.2008.917179
The paper
Shaw, S. R., Leeb, S. B., Norford, L. K., & Cox, R. W. (2008). Nonintrusive Load Monitoring and Diagnostics in Power Systems. IEEE Transactions on Instrumentation and Measurement. https://doi.org/10.1109/tim.2008.917179

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.